Key result
Cardiac CT data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval achieved 87.0% diagnostic accuracy for predicting elevated filling pressure, significantly higher than reconstructions with 3 mm slice thickness.
Why the study?
Does cardiac CT with specific reconstruction parameters accurately estimate diastolic filling pressure compared to echocardiography?
Cross-Sectional (n=46)
Single-blind
No
Does cardiac CT with specific reconstruction parameters accurately estimate diastolic filling pressure compared to echocardiography?
Cardiac CT reconstructed with thin slices (0.9 mm) and frequent sampling (5% RR-interval) optimizes the estimation of diastolic filling pressure compared to echocardiography.
Answers are grounded in this paper and cite their sources.
Optimized thin-slice CT reconstruction may aid noninvasive filling pressure estimation; leaves open prospective validation versus echocardiography.
Objective: To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E'), and E / E' . Materials and Methods: Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RRinterval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm 2 ). E' was calculated from the changes in the left ventricular length per cardiac phase. E / E' was then estimated and compared with that from echocardiography. Results: For assessment of E / E', CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E' 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively. Conclusion: Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E' between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.
No takes yet. Share an insight, caveat, or question.
Hwang et al. (2017) conducted a cross-sectional in Suspected coronary artery disease (n=46). Cardiac CT (0.9 mm slice thickness, 5% RR-interval) vs. Cardiac CT (3 mm slice thickness, 10% RR-interval) was evaluated on Diagnostic accuracy for predicting elevated filling pressure (E/E' ≥ 13) (p=<0.05). Cardiac CT data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval achieved 87.0% diagnostic accuracy for predicting elevated filling pressure, significantly higher than reconstructions with 3 mm slice thickness.