Key result
Baseline q waves in leads I, V5, or V6 predict ~380% higher CRT non-response odds.
Why the study?
The CRT non-response rate can reach 30% in HF patients with LBBB, and the value of baseline q waves in leads I, V5, or V6 for predicting CRT response required evaluation.
Does the presence of baseline q waves in leads I, V5, or V6 predict non-response to cardiac resynchronization therapy in patients with heart failure and left bundle branch block?
Cohort (n=132)
Does the presence of baseline q waves in leads I, V5, or V6 predict non-response to cardiac resynchronization therapy in patients with heart failure and left bundle branch block?
The presence of q waves in lateral and left precordial leads (I, V5, V6) is a strong independent predictor of non-response to cardiac resynchronization therapy in patients with heart failure and left bundle branch block.
Answers are grounded in this paper and cite their sources.
Baseline q waves in I/V5/V6 associated with higher CRT non-response in HF-LBBB; hypothesis-generating and should not yet change selection criteria.
BACKGROUND: The cardiac resynchronization therapy (CRT) non-response rate can reach 30% in heart failure (HF) patients with left bundle branch block (LBBB). This study aimed to evaluate the value of baseline q waves in leads I, V5, or V6 in predicting response to CRT in patients with HF and LBBB. METHODS: Patients with HF (left ventricular ejection fraction ≤35%) and LBBB receiving CRT implantation were retrospectively enrolled. Baseline characteristics and electrocardiogram parameters, including lateral and left precordial q waves were evaluated. Non-response to CRT was defined as the improvement of left ventricular ejection fraction (LVEF) < 5% at a 6-month follow-up. RESULTS: A total of 132 patients (mean age 63.0 ± 10.4 years, 94 [71.2%] male) were included. Among them, 32 patients with q waves in leads I, V5, or V6 were classified into the qLBBB (+) group, and the rest without q waves in these leads were defined as the qLBBB (-) group. The CRT non-response rate in the qLBBB (+) group was markedly higher than that in the qLBBB (-) group (68.8% vs. 33.3%, p < .001). Multivariable logistic regression analysis revealed that the presence of baseline q waves in leads I, V5, or V6 remained significantly associated with a higher rate of CRT non-response in patients with HF and LBBB (odds ratio: 4.8, 95% confidence interval: 1.5-15.0, p = .007). CONCLUSION: Any q wave in leads I, V5, or V6 was an independent predictive factor for CRT non-response in patients with HF and LBBB.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2023) conducted a cohort in Heart failure with left bundle branch block (LBBB) (n=132). Presence of baseline q waves in leads I, V5, or V6 (qLBBB +) vs. Absence of q waves in leads I, V5, or V6 (qLBBB -) was evaluated on Non-response to CRT (improvement of LVEF < 5% at 6-month follow-up) (OR 4.8, 95% CI 1.5-15.0, p=0.007). Baseline q waves in leads I, V5, or V6 independently predicted a higher rate of CRT non-response in patients with heart failure and LBBB.
Synapse has enriched 10 related papers. Consider them for comparative context: