Key result
The Xpert EV assay accurately diagnosed enteroviral meningitis with a sensitivity of 94.69% (90% CI 89.79-97.66%) and specificity of 100% relative to clinical truth.
Why the study?
Does the Xpert EV assay accurately diagnose enteroviral meningitis in patients presenting with meningitis symptoms?
Cross-Sectional (n=434)
Yes
Does the Xpert EV assay accurately diagnose enteroviral meningitis in patients presenting with meningitis symptoms?
The Xpert EV assay provides highly accurate, rapid, and automated detection of enteroviral meningitis, which could improve patient management.
Supports Xpert EV evaluation for enteroviral meningitis diagnosis; leaves open impact on outcomes pending prospective validation.
Nucleic acid amplification tests (NAATs) for enterovirus RNA in cerebrospinal fluid (CSF) have emerged as the new gold standard for diagnosis of enteroviral meningitis, and their use can improve the management and decrease the costs for caring for children with enteroviral meningitis. The Xpert EV assay (Cepheid, Sunnyvale, CA) is a rapid, fully automated real-time PCR test for the detection of enterovirus RNA that was approved by the U.S. Food and Drug Administration for in vitro diagnostic use in March 2007. In this multicenter trial we established the clinical performance characteristics of the Xpert EV assay in patients presenting with meningitis symptoms relative to clinical truth. Clinical truth for enteroviral meningitis was defined as clinical evidence of meningitis, the absence of another detectable pathogen in CSF, and detection of enterovirus in CSF either by two reference NAATs or by viral culture. A total of 199 prospectively and 235 retrospectively collected specimens were eligible for inclusion in this study. The overall prevalence of enteroviral meningitis was 26.04%. The Xpert EV assay had a sensitivity of 94.69% (90% confidence interval [CI] = 89.79 to 97.66%), specificity of 100% (90% CI = 99.07 to 100%), positive predictive value of 100%, negative predictive value of 98.17, and an accuracy of 98.62% relative to clinical truth. The Xpert EV assay demonstrated a high degree of accuracy for diagnosis of enteroviral meningitis. The simplicity and on-demand capability of the Xpert EV assay should prove to be a valuable adjunct to the evaluation of suspected meningitis cases.
No takes yet. Share an insight, caveat, or question.
Nolte et al. (2010) conducted a cross-sectional in Suspected enteroviral meningitis (n=434). Xpert EV assay vs. Clinical truth (two reference NAATs or viral culture) was evaluated on Sensitivity relative to clinical truth (95% CI 89.79-97.66). The Xpert EV assay accurately diagnosed enteroviral meningitis with a sensitivity of 94.69% (90% CI 89.79-97.66%) and specificity of 100% relative to clinical truth.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: