Key result
The improved carbon monoxide rebreathing method was safe in patients with stable coronary artery disease, with cardiovascular function and safety indices remaining unchanged after exposure to ~6% HbCO.
Why the study?
Is the improved CO-rebreathing method safe for measuring total blood volume in patients with stable coronary artery disease?
Is the improved CO-rebreathing method safe for measuring total blood volume in patients with stable coronary artery disease?
The improved CO-rebreathing method for measuring total blood volume appears safe in patients with stable coronary artery disease, without causing myocardial ischemia or arrhythmias.
May support CO-rebreathing for blood volume measurement in stable CAD; leaves open need for larger trials before wider adoption.
PURPOSE: To address and study the safety concerns with the improved carbon monoxide (CO) rebreathing method for measuring total blood volume in patients with coronary artery disease to implement the use of the methodology in this patient group. METHODS: Eighteen patients with stable coronary artery disease (age 62 ± 7 yr, 24 ± 5 months since diagnosis) were investigated using the improved CO-rebreathing test. Before, during, and up to 2 h after the test, ECG, blood pressure, arterial oxygen saturation, carbon monoxide bound to hemoglobin (HbCO%), and cardiac function were measured. At 24 h, HbCO% and troponin-T were measured. DESIGN: Cross-over. RESULTS: Six minutes after the CO-rebreathing test, HbCO increased from 1.5% ± 0.4% to 6.0% ± 0.6%, with a subsequent decrease to 4.5% ± 0.4% and 1.4% ± 0.4% at 2 h and 24 h after the test, respectively. Resting heart rate, stroke volume, cardiac output, and ejection fraction were 64 ± 11 bpm, 93.9 ± 16.5 mL per beat, 5.84 ± 0.99 L, and 48.5% ± 5.7% and remained unchanged during and 10 min after the rebreathing. All patients were in sinus rhythm during the 2-h observation period, without ST- or T-wave changes, with low numbers of premature beats and normal rate variability. Systolic and diastolic blood pressure gradually decreased during the observation period. Troponin-T was below the 99th percentile for all the participants 24 h after the test. CONCLUSION: Cardiovascular function and safety indices remained unchanged after exposure to approximately 6% HbCO, indicating that the method is safe to perform in patients with stable coronary artery disease.
No takes yet. Share an insight, caveat, or question.
Karlsen et al. (2015) studied Stable coronary artery disease (n=18). Improved carbon monoxide (CO) rebreathing method was evaluated on Cardiovascular function and safety indices (including ECG, blood pressure, cardiac function, and troponin-T). The improved carbon monoxide rebreathing method was safe in patients with stable coronary artery disease, with cardiovascular function and safety indices remaining unchanged after exposure to ~6% HbCO.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: