Key result
The S1103Y variant was associated with a higher risk of appropriate ICD therapy for ventricular arrhythmias in Black patients with HFrEF.
Why the study?
Does the S1103Y cardiac sodium channel variant increase the risk of appropriate ICD therapy in Black patients with heart failure and reduced ejection fraction?
Cohort (n=112)
Does the S1103Y cardiac sodium channel variant increase the risk of appropriate ICD therapy in Black patients with heart failure and reduced ejection fraction?
The S1103Y cardiac sodium channel variant is associated with a more than 4-fold increased risk of ventricular arrhythmias requiring ICD therapy in Black patients with HFrEF.
Answers are grounded in this paper and cite their sources.
May inform arrhythmia risk stratification in Black HFrEF patients; hypothesis-generating for genotype-guided interventions.
BACKGROUND: Risk-stratifying heart failure patients for primary prevention implantable cardioverter-defibrillators (ICDs) remains a challenge, especially for blacks, who have an increased incidence of sudden cardiac death but have been underrepresented in clinical trials. We hypothesized that the S1103Y cardiac sodium channel SCN5A variant influences the propensity for ventricular arrhythmias in black patients with heart failure and reduced ejection fraction. METHODS AND RESULTS: Blacks (n=112) with ejection fractions <35% receiving primary prevention ICDs were identified from the Duke Electrophysiology Genetic and Genomic Studies (EPGEN) biorepository and followed for appropriate ICD therapy (either anti tachycardia pacing or shock) for documented sustained ventricular tachycardia or fibrillation. The S1103Y variant was overrepresented in patients receiving appropriate ICD therapy compared with subjects who did not (35% versus 13%, P=0.03). Controlling for baseline characteristics, the adjusted hazard ratio using a Cox proportional hazard model for ICD therapy in Y1103 allele carriers was 4.33 (95% confidence interval, 1.60 to 11.73, P=<0.01). There was no difference in mortality between carriers and noncarriers. CONCLUSIONS: This is the first report that the S1103Y variant is associated with a higher incidence of ventricular arrhythmias in blacks with heart failure and reduced ejection fraction.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2011) conducted a cohort in Heart failure with reduced ejection fraction (n=112). S1103Y SCN5A variant vs. Noncarriers was evaluated on Appropriate ICD therapy (anti tachycardia pacing or shock) for documented sustained ventricular tachycardia or fibrillation (HR 4.33, 95% CI 1.60-11.73, p=<0.01). The S1103Y variant was associated with a higher risk of appropriate ICD therapy for ventricular arrhythmias in Black patients with HFrEF.
Synapse has enriched 10 related papers. Consider them for comparative context: