Why the study?
Does using myocardial salvage index (MSI) by CMR reduce the required sample size in cardioprotection trials compared to MI size alone or biochemical markers?
Does using myocardial salvage index (MSI) by CMR reduce the required sample size in cardioprotection trials compared to MI size alone or biochemical markers?
Using myocardial salvage index by CMR as an endpoint in cardioprotection trials can reduce required sample sizes by 46% to 65% compared to MI size alone or biochemical markers.
Answers are grounded in this paper and cite their sources.
MSI by CMR may enable smaller cardioprotection trials; leaves open prospective validation of efficiency gains.
BACKGROUND: Cardiac magnetic resonance (CMR) can quantify myocardial infarct (MI) size and myocardium at risk (MaR), enabling assessment of myocardial salvage index (MSI). We assessed how MSI impacts the number of patients needed to reach statistical power in relation to MI size alone and levels of biochemical markers in clinical cardioprotection trials and how scan day affect sample size. METHODS AND RESULTS: Controls (n=90) from the recent CHILL-MI and MITOCARE trials were included. MI size, MaR, and MSI were assessed from CMR. High-sensitivity troponin T (hsTnT) and creatine kinase isoenzyme MB (CKMB) levels were assessed in CHILL-MI patients (n=50). Utilizing distribution of these variables, 100 000 clinical trials were simulated for calculation of sample size required to reach sufficient power. For a treatment effect of 25% decrease in outcome variables, 50 patients were required in each arm using MSI compared to 93, 98, 120, 141, and 143 for MI size alone, hsTnT (area under the curve [AUC] and peak), and CKMB (AUC and peak) in order to reach a power of 90%. If average CMR scan day between treatment and control arms differed by 1 day, sample size needs to be increased by 54% (77 vs 50) to avoid scan day bias masking a treatment effect of 25%. CONCLUSION: Sample size in cardioprotection trials can be reduced 46% to 65% without compromising statistical power when using MSI by CMR as an outcome variable instead of MI size alone or biochemical markers. It is essential to ensure lack of bias in scan day between treatment and control arms to avoid compromising statistical power.
No takes yet. Share an insight, caveat, or question.
Engblom et al. (2016) studied this question.