Key result
Phenylephrine fails to resolve aortic stenosis grading discrepancies between pre-CPB TEE and preoperative TTE.
Why the study?
Aortic stenosis grading discrepancies exist between pre-CPB TEE and preoperative TTE, but prior studies have not systematically controlled blood pressure.
Does normalizing arterial blood pressure with phenylephrine during pre-CPB TEE prevent grading discrepancies in aortic stenosis compared to preoperative TTE in adults undergoing valve replacement?
Does normalizing arterial blood pressure with phenylephrine during pre-CPB TEE prevent grading discrepancies in aortic stenosis compared to preoperative TTE in adults undergoing valve replacement?
Normalizing blood pressure with phenylephrine during pre-CPB TEE does not resolve discrepancies in aortic stenosis grading for velocity and gradient compared to preoperative TTE, suggesting aortic valve area may be a more reliable parameter under general anesthesia.
Answers are grounded in this paper and cite their sources.
BP normalization with phenylephrine does not resolve TEE-TTE aortic stenosis grading discrepancies; leaves open need for alternative standardization approaches in perioperative assessment.
Background: Aortic stenosis (AS) grading discrepancies exist between pre-cardiopulmonary (pre-CPB) transesophageal echocardiography (TEE) and preoperative transthoracic echocardiography (TTE). Prior studies have not systematically controlled blood pressure. Aims: We hypothesized that normalizing arterial blood pressure during pre-CPB TEE for patients undergoing valve replacement for AS would result in equivalent grading measurements when compared to TTE. Setting: Single University Hospital Design: Prospective, Interventional Methods: Thirty-five adult patients underwent procedures for valvular AS between February 2017 and December 2020 at Medical University of South Carolina. Study participants had a TTE within 90 days of their procedure that documented blood pressure, peak velocity (V p ), mean gradient (PG m ), aortic valve area (AVA), and dimensionless index (DI). During pre-CPB TEE, if a patient’s mean arterial pressure (MAP) fell more than 20% below their baseline blood pressure obtained during TTE, measurements were recorded as “out of range.” Phenylephrine was administered to restore MAP to the baseline range and repeat TEE measurements were recorded as “in-range.” Statistical Analysis: Differences between imaging modalities and grading parameters were examined using a series of linear mixed models. P values were Bonferroni-adjusted to account for multiple comparisons. Main Results: Significant discrepancies between TEE and TTE were observed for V p , PG m , and DI despite blood pressure normalization across all subjects and for out-of-range measures and corrected measures. There were no statistically significant differences between TEE and TTE for AVA. Conclusions: Blood pressure normalization during pre-CPB TEE is not sufficient to avoid AS grading discrepancies with preoperative TTE.
No takes yet. Share an insight, caveat, or question.
Whitener et al. (2023) studied Aortic stenosis (n=35). Blood pressure normalization with phenylephrine during pre-CPB TEE vs. Preoperative TTE was evaluated on Difference in peak velocity (Vp) between in-range pre-CPB TEE and preoperative TTE (MD -0.32 m/s, 95% CI -0.45, -0.19, p=<0.05). Normalizing blood pressure with phenylephrine during pre-cardiopulmonary bypass transesophageal echocardiography did not eliminate significant grading discrepancies in peak velocity, mean gradient, and dimensionless index compared to preoperative transthoracic echocardiography.
Synapse has enriched 10 related papers. Consider them for comparative context: