K-space segmented cine sequences reduced measuring time to 20-40% of conventional sequences, with similar image quality in subjects with EF ≥60% but degraded results in those with EF <60% (P<0.001).
Why the study?
Does k-space segmented cine imaging maintain image quality compared to conventional gradient-echo sequences in subjects undergoing functional cardiac MRI?
Cross-Sectional (n=31)
Does k-space segmented cine imaging maintain image quality compared to conventional gradient-echo sequences in subjects undergoing functional cardiac MRI?
Answers are grounded in this paper and cite their sources.
K-space segmented cine MRI significantly reduces scan time but yields degraded image quality in patients with reduced ejection fraction compared to conventional sequences.
RATIONALE AND OBJECTIVES: In functional cardiac magnetic resonance imaging, reduction of measuring time is very important for many patients who are not able to rest motionless for long-lasting examinations. In this study, the image quality of sequences with k-space segmented data recording was compared with conventional gradient-echo sequences for cine imaging with flow compensation in applications on patients with normal and reduced ejection fractions. METHODS: Thirty-one subjects (4 volunteers and 27 patients with cardiac diseases) were examined using different techniques for cine imaging of the left and right ventricles. The ejection fraction in the patients was calculated based on images of a conventional two-dimensional gradient-echo technique using a biplane ellipsoid model. The results from k-space segmented methods (3 to 9 Fourier lines per cardiac cycle for each phase image) were compared with the conventional images of the same short-axis view separately for groups of subjects with normal and reduced ejection fraction. The contrast between blood and myocardium at several sites of the heart and the homogeneity of the blood signal in the ventricle were evaluated for several phases of the heart cycle. RESULTS: The segmentation in the acquisition of raw data allows reduction of measuring time to approximately 20% to 40% of the time required for conventional sequences in cine imaging of the heart. In patients with normal or only slightly reduced heart function (ejection fraction > or = 60%) the image quality of k-space segmented sequences was not significantly different from the conventionally recorded images. In contrast, patients with markedly lowered ejection fraction (< 60%) showed degraded results of the k-space segmented sequences compared with the conventional sequence (P < 0.001). The anterolateral border and the right ventricle especially were not sufficiently delineated by the k-space segmented sequences in these patients. CONCLUSION: The k-space segmentation for the reduction of examination time is suitable for measuring heart volumes and functional parameters of patients expected to have a nearly normal ejection fraction, whereas for patients with markedly reduced cardiac function further technical improvements of segmented techniques are necessary.
No takes yet. Share an insight, caveat, or question.
SCHÜLEN et al. (1996) conducted a cross-sectional in Cardiac diseases (n=31). K-space segmented cine sequences vs. Conventional gradient-echo sequences was evaluated on Image quality, contrast between blood and myocardium, and homogeneity of blood signal (p=<0.001). K-space segmented cine sequences reduced measuring time to 20-40% of conventional sequences, with similar image quality in subjects with EF ≥60% but degraded results in those with EF <60% (P<0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: