Key result
Balloon aortic valvuloplasty had low procedural mortality (0.5%) but high overall 12-month mortality (36%), with active malignancy (OR 4.4) and smoking history (OR 3.3) as significant predictors.
Why the study?
BAV has seen renewed interest since the advent of TAVI, prompting the need to characterise a contemporary BAV cohort and determinants of clinical outcomes.
Cohort (n=224)
No
Balloon aortic valvuloplasty remains a useful bridging or palliative procedure with low procedural complications, though 1-year mortality remains high, particularly in patients with active malignancy, low LVEF, or when used as destination therapy.
High post-BAV mortality with malignancy or smoking warrants cautious selection; hypothesis-generating for risk stratification in prospective studies.
BACKGROUND: Balloon aortic valvuloplasty (BAV) has seen renewed interest since the advent of transcatheter aortic valve implantation (TAVI). The study aimed to characterise a contemporary BAV cohort and determinants of clinical outcomes. METHODS: Patients undergoing BAV at a single tertiary centre were retrospectively reviewed over a 10-year period, and functional and mortality outcomes were reported with up to a 2-year follow-up. RESULTS: 224 patients (aged 82.5±8.3 years; 48% female) underwent BAV over the study period. Indications were either destination treatment (39%) or bridge-to-valve replacement (61%)-including bridge-to-decision (29%), symptom relief while on the waitlist (27%), and temporary contraindications to TAVI/aortic valve replacement (AVR) (5%). The mean reduction of aortic mean pressure gradient was 38%. Procedural mortality occurred in 0.5%, stroke in 1.3%, and major bleeding in 0.9%. Twelve-month mortality was 36% overall, and 26% and 50% in the bridging and destination groups, respectively. New York HeartAssociation (NYHA) class improved by ≥1 at 30 days in 50%. Among the bridge-to-TAVI/AVR group, 40% proceeded to TAVI/AVR within 12 months following BAV. In multivariate analysis, active malignancy at baseline (OR: 4.4, 95% CI: 1.3 to 15.1, p=0.02), smoking history (OR: 3.3, 95% CI: 1.3 to 7.9, p<0.01), LVEF ≤30% at baseline (OR: 3.2, 95% CI: 1.3 to 7.6, p<0.01), destination treatment (OR: 2.2, 95% CI: 1.0 to 4.9, p=0.04) were all associated with 12-month mortality. CONCLUSIONS: BAV remains a useful procedure with relatively low rates of complications, however, 1-year mortality rates are high. Contemporary indications for BAV include a bridge to definitive valve replacement or destination treatment.
No takes yet. Share an insight, caveat, or question.
Dawson et al. (2020) conducted a cohort in Aortic stenosis (n=224). Balloon aortic valvuloplasty (BAV) was evaluated on 12-month mortality. Balloon aortic valvuloplasty had low procedural mortality (0.5%) but high overall 12-month mortality (36%), with active malignancy (OR 4.4) and smoking history (OR 3.3) as significant predictors.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: