Key result
FDG PET-assisted management fails to reduce major cardiac events compared to standard care.
Why the study?
Does F-18-fluorodeoxyglucose PET-assisted management reduce the composite of cardiac death, myocardial infarction, or recurrent hospital stay for cardiac cause in patients with severe left ventricular dysfunction and suspected coronary disease?
RCT (n=430)
Stratified
Does F-18-fluorodeoxyglucose PET-assisted management reduce the composite of cardiac death, myocardial infarction, or recurrent hospital stay for cardiac cause in patients with severe left ventricular dysfunction and suspected coronary disease?
Answers are grounded in this paper and cite their sources.
F-18-fluorodeoxyglucose PET-assisted management did not significantly reduce 1-year cardiac events compared to standard care in patients with severe LV dysfunction and suspected coronary disease.
OBJECTIVES: We conducted a randomized trial to assess the effectiveness of F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET)-assisted management in patients with severe ventricular dysfunction and suspected coronary disease. BACKGROUND: Such patients may benefit from revascularization, but have significant perioperative morbidity and mortality. F-18-fluorodeoxyglucose PET can detect viable myocardium that might recover after revascularization. METHODS: Included were patients with severe left ventricular (LV) dysfunction and suspected coronary disease being considered for revascularization, heart failure, or transplantation work-ups or in whom PET was considered potentially useful. Patients were stratified according to recent angiography or not, then randomized to management assisted by FDG PET (n = 218) or standard care (n = 212). The primary outcome was the composite of cardiac death, myocardial infarction, or recurrent hospital stay for cardiac cause, within 1 year. RESULTS: At 1 year, the cumulative proportion of patients who had experienced the composite event was 30% (PET arm) versus 36% (standard arm) (relative risk 0.82, 95% confidence interval [CI] 0.59 to 1.14; p = 0.16). The hazard ratio (HR) for the composite outcome, PET versus standard care, was 0.78 (95% CI 0.58 to 1.1; p = 0.15); for patients that adhered to PET recommendations for revascularization, revascularization work-up, or neither, HR = 0.62 (95% CI 0.42 to 0.93; p = 0.019); in those without recent angiography, for cardiac death, HR = 0.4 (95% CI 0.17 to 0.96; p = 0.035). CONCLUSIONS: This study did not demonstrate a significant reduction in cardiac events in patients with LV dysfunction and suspected coronary disease for FDG PET-assisted management versus standard care. In those who adhered to PET recommendations and in patients without recent angiography, significant benefits were observed. The utility of FDG PET is best realized in this subpopulation and when adherence to recommendations can be achieved.
No takes yet. Share an insight, caveat, or question.
Beanlands et al. (2007) conducted an RCT in Severe left ventricular dysfunction and suspected coronary disease (n=430). F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET)-assisted management vs. Standard care was evaluated on Composite of cardiac death, myocardial infarction, or recurrent hospital stay for cardiac cause, within 1 year (HR 0.78, 95% CI 0.58-1.1, p=0.15). FDG PET-assisted management did not reduce cardiac death, MI, or recurrent cardiac hospitalization compared to standard care.
Synapse has enriched 10 related papers. Consider them for comparative context: