Key result
Following 50 W HPSD ablation for atrial fibrillation, AF recurrence occurred in 3.75% of patients, with 11 of 12 reablated patients showing chronic isolation of all four pulmonary veins.
Why the study?
Little is known regarding the mid- to long-term effects of high-power-short-duration RF ablation for pulmonary vein isolation and left atrial substrate modification.
Does CLOSE-guided 50 W HPSD ablation prevent pulmonary vein reconnection in patients with atrial fibrillation?
Observational (n=400)
No
Does CLOSE-guided 50 W HPSD ablation prevent pulmonary vein reconnection in patients with atrial fibrillation?
Atrial fibrillation recurrence after 50 W HPSD pulmonary vein isolation is predominantly driven by progressive fibrous atrial cardiomyopathy rather than pulmonary vein reconnection, which appears to be rare.
Answers are grounded in this paper and cite their sources.
PV reconnection rare after HPSD PVI; leaves open durability impact on overall recurrence in broader AF populations.
INTRODUCTION: Ablation of atrial fibrillation (AF) with high-power-short-duration (HPSD) radiofrequency (RF) technology is emerging as a new standard of care in many electrophysiology laboratories. While procedural short-term efficacy and efficiency is very promising, little is known about mid- to long-term effects of HPSD ablation for pulmonary vein isolation (PVI) and left atrial substrate modification. METHODS: In a single-center registry, 412 AF procedures were performed in 400 individual patients using a standardized CLOSE protocol-guided fixed 50 W HPSD ablation, aiming for an ablation index (AI) of 400 on the posterior and 550 on the anterior wall. Additional substrate-tailored lines were performed when required. RESULTS: After a mean clinical follow-up of 337 ± 134 days, 15 patients suffered from AF recurrence beyond the blinding period. Twelve gave consent to the indicated reablation. Here, 11 of 12 patients had chronic isolation of all four pulmonary veins (PV). In three of six patients, a reconnection of additional left atrial ablation lines was revealed. Ten out of 12 patients showed progressive fibrous atrial cardiomyopathy and required additional left atrial substrate modification or reisolation of left-atrial lines. During the follow-up no clinical case of atrioesophageal fistula was registered. No PV stenosis after initial HPSD PVI was documented. CONCLUSIONS: Patients requiring reablation of AF or other atrial tachycardia after a fixed 50 W HPSD circumferential PVI and substrate modification predominantly suffer from progressive fibrous atrial cardiomyopathy, while PV reconnection appears to be a rare cause of AF recurrence.
No takes yet. Share an insight, caveat, or question.
Francke et al. (2022) conducted an observational in Atrial fibrillation (n=400). CLOSE protocol-guided fixed 50 W high-power-short-duration (HPSD) ablation was evaluated on AF recurrence beyond the blinding period. Following 50 W HPSD ablation for atrial fibrillation, AF recurrence occurred in 3.75% of patients, with 11 of 12 reablated patients showing chronic isolation of all four pulmonary veins.
Synapse has enriched 10 related papers. Consider them for comparative context: