Key result
The colloidal gold immunochromatography assay coated by EV71-VP1-VP2-VP3 demonstrated 20% higher accuracy than EV71-VP1 strips and significantly higher accuracy than commercial strips.
Why the study?
Does the developed colloidal gold immunochromatography assay improve the accuracy of detecting EV71-IgM in serum samples compared to commercial strips?
Does the developed colloidal gold immunochromatography assay improve the accuracy of detecting EV71-IgM in serum samples compared to commercial strips?
The newly developed colloidal gold immunochromatography assay using EV71-VP1-VP2-VP3 coating provides higher accuracy for early diagnosis of EV71-induced HFMD using only 2 µL of serum.
Answers are grounded in this paper and cite their sources.
This assay may enable low-volume EV71-IgM detection; leaves open prospective clinical validation before diagnostic adoption.
Aim: The HFMD caused by EV71 virus has extremely high lethality and morbidity. EV71's pathogenesis has not understood thoroughly and the antiviral drug has been under development, which led to its emergence as a clinically fatal neurotropic virus. Early diagnosis is one of the main methods to reduce mortality. The aim of this study was to establish and evaluate a colloidal gold immunochromatography for qualitatively detecting the EV71-IgM in serum sample. Method: In this study, the different kinds of coating antigen were the focus of optimization. The pH value, particle size of the colloidal gold and other parameters and materials were also considered to achieve the good performance in detecting strips. The CA16-positive, EV71-positive and negative serum were used to compare and evaluate the accuracy and specificity of strips. Result: The accuracy of the strips coated by EV71-VP1-VP2-VP3 was higher than the EV71-VP1 strips 20%. The specificity of the EV71-VP1 strips was slightly higher than EV71-VP1-VP2-VP3 strips according to CA16 positive serum samples. Compared with commercial strips, this diagnostic method just needed 2 µL serum samples for detection, and the accuracy of the EV71-VP1-VP2-VP3 strips was significantly higher than the commercial strips. Conclusion: The developed method established in this study can apply to early diagnosis of HFMD caused by EV71 virus.
No takes yet. Share an insight, caveat, or question.
Junwei Liu (2018) studied Hand, foot, and mouth disease (HFMD) caused by EV71 virus. Colloidal gold immunochromatography assay coated by EV71-VP1-VP2-VP3 vs. EV71-VP1 strips and commercial strips was evaluated on Accuracy and specificity of strips. The colloidal gold immunochromatography assay coated by EV71-VP1-VP2-VP3 demonstrated 20% higher accuracy than EV71-VP1 strips and significantly higher accuracy than commercial strips.
Synapse has enriched 10 related papers. Consider them for comparative context: