Key result
A high-throughput LC-MS/MS method was successfully developed and validated in 3 patients for the simultaneous detection of clopidogrel, 2-oxo-clopidogrel, and its active metabolite.
Why the study?
Clopidogrel requires a two-step metabolism to generate its active thiol metabolite, and an efficient method was needed to simultaneously measure plasma clopidogrel, 2-oxo-clopidogrel, and the active metabolite.
A newly developed LC-MS/MS method allows for the efficient and simultaneous detection of clopidogrel and its key metabolites in human plasma.
Answers are grounded in this paper and cite their sources.
May enable efficient metabolite monitoring in research; leaves open clinical utility pending larger validation studies.
Clopidogrel is a pro-drug which needs two-step metabolism to produce the active thiol metabolite. This study aimed to explore an efficient method to simultaneously determine the plasma clopidogrel, 2-oxo-clopidogrel (2-Oxo-CLP), and the clopidogrel active metabolite (CAM). A high-throughput liquid chromatography tandem mass spectrometry (LC-MS/MS) was therefore developed. The analytes were extracted from plasma by using methyl tert-butyl ether (MTBE). Chromatographic separation was performed on a C18 column under an isocratic elution, accompanied with acetonitrile and deionized water containing 0.1% formic acid. After optimizing the condition of LC-MS/MS, a stable linearity was observed in the standard curves over the concentration ranges of 0.05 to 50.0 ng/mL for clopidogrel, 0.5 to 50.0 ng/mL for 2-Oxo-CLP, and 0.5 to 100 ng/mL for clopidogrel active metabolite derivative (CAMD). The retention time was 4.78 minutes, 3.79 minutes, 3.59 minutes, and 4.82 minutes for clopidogrel, 2-Oxo-CLP, CAMD, and internal standard, respectively. Both the relative standard deviation and the relative error were within the requirement of operating criteria. No significant degradation of clopidogrel, 2-Oxo-CLP, and CAMD occurred under different storage conditions. This method was successfully validated in 3 patients with coronary artery disease. The results showed that the current LC-MS/MS method was efficient for simultaneously detecting clopidogrel, 2-Oxo-CLP, and CAM with fine linearity, accuracy, precision, and stability.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2022) studied Coronary artery disease (n=3). LC-MS/MS method for clopidogrel and metabolites was evaluated on Method linearity, accuracy, precision, and stability. A high-throughput LC-MS/MS method was successfully developed and validated in 3 patients for the simultaneous detection of clopidogrel, 2-oxo-clopidogrel, and its active metabolite.
Synapse has enriched 10 related papers. Consider them for comparative context: