Key result
A rapid and sensitive LC-MS/MS method was developed for determining clopidogrel carboxylic acid in human plasma, with a lower limit of quantification of 25 ng/ml and good linearity.
A rapid and sensitive LC-MS/MS method was successfully developed and validated for quantifying clopidogrel carboxylic acid in human plasma, suitable for pharmacokinetic studies and therapeutic drug monitoring.
May support clopidogrel pharmacokinetic studies and therapeutic monitoring; leaves open clinical validation before routine use.
Background: Clopidogrel, is a thienopyridine derivative labeled for use to prevent thrombosis after coronary artery stenting. Pharmacokinetics of clopidogrel is studied indirectly by quantification of carboxylic acid which is a major metabolite of Clopidogrel. Objective: The aim of this work is to develop and validate a rapid, simple and sensitive LC/MS/MS assay method for the determination of Clopidogrel carboxylic acid in human plasma using Clopidogrel-D4-carboxylic acid as internal standard. Methods: Analytes was extracted from 200 μl of plasma by a simple liquid-liquid extraction using diethyl ether – n-hexane (80:20, v/v). The chromatographic separations were achieved on a C18 column using Methanol, de-ionized water and formic acid as a mobile phase at flow rate of 0.5 ml/minute. Analysis was monitored by multiple reactions monitoring mode based on m/z transition of 308.10→113 for Clopidogrel carboxylic acid and 312.10→129 for internal standard. Result: The method had a total run time of about 4 minutes. The lower limit of quantification (LLOQ) was 25 ng/ml showing good linearity over the working range of 25 – 3000 ng/ml (r ≥ 0.999). The intra- and inter day accuracies were 90% - 98% and 92.138% - 96.889% respectively (deviation within acceptable range ≤ 10%).Conclusion: It was shown that this method is suitable for pharmacokinetic study following oral administration of Clopidogrel and can be successfully applied to the therapeutic drug monitoring of Clopidogrel in Clopidogrel-treated patients.
No takes yet. Share an insight, caveat, or question.
El-Sadek et al. (2011) studied this question. LC-MS/MS assay for Clopidogrel carboxylic acid was evaluated on Assay performance (LLOQ, linearity, accuracy). A rapid and sensitive LC-MS/MS method was developed for determining clopidogrel carboxylic acid in human plasma, with a lower limit of quantification of 25 ng/ml and good linearity.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: