Key result
Voltage clamp analysis of rabbit sinoatrial node cells revealed two distinct pacemaker cell types: Type I with only slow inward current, and Type II with both fast transient and slow inward currents.
The study identifies two electrophysiologically distinct types of pacemaker cells in the rabbit sinoatrial node, clarifying the differential presence of the fast transient inward sodium current in dominant versus subsidiary pacemakers.
Answers are grounded in this paper and cite their sources.
No iNa in dominant SAN cells; leaves open its role in pacemaking and requires intact-tissue validation.
Previous investigations employing multicellular nodal preparations (i.e., mixtures of dominant and subsidiary pacemaker cells) have suggested that the fast transient inward sodium current (iNa) either is not present in dominant pacemaker cells or is present but inactivated at the depolarized take-off potentials that these cells exhibit. In the present study, this question was resolved by voltage clamp analysis of single pacemaker cells isolated from the sinoatrial node and maintained in vitro for 1-3 days. Two types of cells, each with a different morphology, exhibited two modes of electrophysiological behavior. Type I cells (presumably dominant pacemakers) displayed only a tetrodotoxin (TTX)-resistant (but cadmium-sensitive) slow inward current, whereas type II cells (presumably subsidiary pacemakers) exhibited two components of inward current, a TTX-sensitive, fast transient inward current and a TTX-resistant (but cadmium-sensitive) slow inward current. Three other voltage-gated currents, 1) a slowly developing inward current activated by hyperpolarization (if, ih, delta ip), 2) a transient outward current activated by strong depolarization (ito, iA), and 3) a delayed outward current, were recorded in both types of pacemaker cells.
No takes yet. Share an insight, caveat, or question.
Richard D. Nathan (1986) studied this question. Voltage clamp analysis was evaluated on Electrophysiological behavior and inward currents. Voltage clamp analysis of rabbit sinoatrial node cells revealed two distinct pacemaker cell types: Type I with only slow inward current, and Type II with both fast transient and slow inward currents.