A significant proportion of intraoperative procedures do not meet the criteria for dynamic fluid responsiveness monitoring, limiting its widespread applicability in general anesthesia.
Answers are grounded in this paper and cite their sources.
Limits applicability of dynamic fluid responsiveness monitoring in routine anesthesia; leaves open targeted use pending prospective validation.
Dynamic variables are the best predictors of fluid responsiveness in patients under general anesthesia and mechanical ventilation; namely, respiratory variations in pulse pressure and in the plethysmographic waveform. However, these variables have potential limitations. Our aim was to evaluate their intraoperative applicability. We extracted clinical data from all anesthesia procedures performed at our institution in 2009 and identified the number of cases that presented predetermined conditions of application. Among the 12,308 procedures, 39% met the criteria for the noninvasive monitoring of variations in the plethysmographic waveform of which 23% had arterial lines and met the criteria for the invasive monitoring of variations in pulse pressure.