Why the study?
Do OCT-derived lipidic plaque and minimum lumen area predict angiographic late stent edge restenosis in patients undergoing everolimus-eluting stent implantation?
Do OCT-derived lipidic plaque and minimum lumen area predict angiographic late stent edge restenosis in patients undergoing everolimus-eluting stent implantation?
OCT-derived lipidic plaque and smaller minimum lumen area at stent edges post-implantation are independent predictors of late stent edge restenosis, highlighting the utility of OCT in selecting appropriate landing zones.
Answers are grounded in this paper and cite their sources.
OCT edge features may flag late SER risk after everolimus-eluting stents; leaves open whether OCT-guided optimization improves outcomes.
Background— Stent edge restenosis (SER) remains a potential limitation of drug-eluting stents. The aim of this study was to determine optical coherence tomography (OCT) predictors for angiographic late SER after everolimus-eluting stent implantation. Methods and Results— We retrospectively analyzed 319 patients who underwent OCT immediately after everolimus-eluting stent implantation and scheduled 9- to 12-month follow-up angiography. The binary angiographic SER rate was 10% (32/319) in the patients, 8.4% (32/382) in lesions, and 4.4% (33/744) in stent edge segments. In the stent edge segments at post stenting, OCT-derived lipidic plaque (61% versus 20%; P <0.001) was more often observed in the SER group, and OCT-measured minimum lumen area (4.13±2.61 versus 5.58±2.46 mm 2 ; P =0.001) was significantly smaller in the SER group compared with the non-SER group. Multivariate analysis identified lipidic plaque (odds ratio: 5.99; 95% confidence interval: 2.89–12.81; P <0.001) and minimum lumen area (odds ratio: 0.64; 95% confidence interval: 0.42–0.96; P =0.029) as independent predictors of binary SER. Receiver-operating characteristic analysis demonstrated that lipid arc of 185° (sensitivity: 71%; specificity: 72%; area under the curve: 0.761) and minimum lumen area of 4.10 mm 2 (sensitivity: 67%; specificity: 77%; area under the curve: 0.787) were optimal cutoff values for predicting ischemia-driven SER. Conclusions— The present OCT study demonstrated that lipidic plaque and minimum lumen area in the stent edge segments at post stenting were associated with late SER after everolimus-eluting stent implantation. OCT provides valuable information to determine an appropriate landing zone for stent implantation.
No takes yet. Share an insight, caveat, or question.
Ino et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: