Key result
The presence of ruptured plaque before intervention and higher total cholesterol levels were independent predictors of irregular protrusion immediately after cobalt-chromium everolimus-eluting stent implantation in patients with stable coronary artery disease.
Why the study?
Predictors of irregular protrusion immediately after stent implantation based on clinical and preintervention optical coherence tomography findings were not fully established.
What are the clinical and preintervention OCT predictors of irregular protrusion after everolimus-eluting stent implantation in patients with stable coronary artery disease?
Observational (n=84)
Yes
What are the clinical and preintervention OCT predictors of irregular protrusion after everolimus-eluting stent implantation in patients with stable coronary artery disease?
Pre-intervention ruptured plaque and higher total cholesterol levels independently predict irregular protrusion after everolimus-eluting stent implantation in stable coronary artery disease.
Answers are grounded in this paper and cite their sources.
Ruptured plaque and higher cholesterol predict post-stent IRP; hypothesis-generating for OCT-guided strategies in stable CAD.
This study aimed to investigate clinical and preintervention optical coherence tomography (OCT) findings to predict irregular protrusion (IRP) immediately after stent implantation.We evaluated 84 lesions treated with cobalt-chromium everolimus-eluting stent (CoCr-EES) from the MECHANISM Elective study. Patients were divided into two groups according to the presence of IRP [IRP: n = 16, non-IRP: n = 68]. Optical coherence tomography images before intervention and immediately after stenting were evaluated with standard qualitative and quantitative OCT analyses.Total cholesterol and the prevalence of ruptured plaque before intervention were significantly higher in the IRP group than in the non-IRP group [199 ± 37 mg/dL versus 176 ± 41 mg/dL; P = 0.022, 31% versus 7%; P = 0.008]. Total lipid length tended to be longer in the IRP group than in the non-IRP group [19.6 ± 9.2 mm versus 15.5 ± 9.3 mm; P = 0.090]. The prevalence of ruptured plaque, and total cholesterol levels were independent predictors of IRP immediately after stenting by multivariate logistic regression analysis [OR: 4.6, 95% confidence interval: 1.01-21.23, P = 0.048, OR: 1.02, 95% confidence interval: 1.00-1.03, P = 0.046]. IRP post-CoCr-EES implantation was completely resolved at follow-up OCT.The prevalence of ruptured plaque before intervention and total cholesterol levels were independent predictors of IRP after CoCr-EES implantation in patients with stable coronary artery disease.
No takes yet. Share an insight, caveat, or question.
Taguchi et al. (2022) conducted an observational in Stable coronary artery disease (n=84). Ruptured plaque before intervention vs. No ruptured plaque before intervention was evaluated on Irregular protrusion (IRP) immediately after stent implantation (OR 4.6, 95% CI 1.01-21.23, p=0.048). The presence of ruptured plaque before intervention and higher total cholesterol levels were independent predictors of irregular protrusion immediately after cobalt-chromium everolimus-eluting stent implantation in patients with stable coronary artery disease.