Answers are grounded in this paper and cite their sources.
Electromechanical coupling and stretch-activated currents can alter conduction velocity restitution, potentially playing a role in the transition to reentry and fibrillation.
In this paper we use a simplified model of cardiac excitation-contraction coupling to study the effect of tissue deformation on the dynamics of alternans, i.e., alternations in the duration of the cardiac action potential, that occur at fast pacing rates and are known to be proarrhythmic. We show that small stretch-activated currents can produce large effects and cause a transition from in-phase to off-phase alternations (i.e., from concordant to discordant alternans) and to conduction blocks. We demonstrate numerically and analytically that this effect is the result of a generic change in the slope of the conduction velocity restitution curve due to electromechanical coupling. Thus, excitation-contraction coupling can potentially play a relevant role in the transition to reentry and fibrillation.
No takes yet. Share an insight, caveat, or question.
Radszuweit et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: