Why the study?
Despite continued efforts, a majority of patients with valvular heart disease remain undiagnosed and untreated.
Does point-of-care ultrasound by briefly trained primary care providers accurately screen for valvular heart disease compared to expert readers?
Does point-of-care ultrasound by briefly trained primary care providers accurately screen for valvular heart disease compared to expert readers?
Point-of-care echocardiography by trained primary care providers demonstrates high diagnostic accuracy for most structural heart assessments, though accuracy for aortic stenosis remains weak.
Answers are grounded in this paper and cite their sources.
POCE by untrained primary care providers warrants further validation; leaves open accuracy, adoptability, and clinical impact.
PURPOSE: Despite continued efforts, a majority of patients with valvular heart disease (VHD) remain undiagnosed and untreated. This study aimed to assess the adoptability and accuracy of point-of-care handheld echocardiographic assessments (POCE) in the primary care setting. METHODS: Eleven previously untrained primary care providers were trained to use the Vscan Extend (GE, WI) POCE to assess VHD, left ventricular function (LVEF), and major extra-cardiac findings. Their assessments were compared to those of three blinded expert readers. A total of 175 patients underwent POCE assessments which were evaluated using Kappa statistics (κ) together with their estimated standard error, p value, and 95% CI bounds. RESULTS: Each patient had a mean of 3.3 ± 1.1 (±SD) assessments performed. Identical or nearly identical agreement between previously untrained primary providers and expert readers was evident for the diagnosis of tricuspid regurgitation, mitral regurgitation, pericardial effusion, and volume status. These agreements were strongest in apical long axis (κ = 1, p < 0.001) and parasternal long and short axis views (κ > =0.82 p < 0.001), though agreement remained robust in apical 4-chamber views (κ ≥ 0.76). The agreements in LVEF assessment were identical in the apical long axis view (κ = 1, p < 0.001) and robust in the remaining 3 views (κ > =0.66, p < 0.001). The assessments of aortic stenosis (parasternal/long, κ = 0.42, and parasternal/short, κ = 0.47, both p < 0.001) were weak in their agreement. CONCLUSION: Compared to expert echocardiography readers, the untrained providers' use of POCE for VHD shows high user adoptability and diagnostic accuracies in the primary care setting.
No takes yet. Share an insight, caveat, or question.
Chugh et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: