Why the study?
Does a processing-independent proANP assay perform similarly to an MR-proANP assay for detecting left ventricular dysfunction and predicting cardiovascular mortality in elderly patients with heart failure symptoms?
Does a processing-independent proANP assay perform similarly to an MR-proANP assay for detecting left ventricular dysfunction and predicting cardiovascular mortality in elderly patients with heart failure symptoms?
Answers are grounded in this paper and cite their sources.
A new processing-independent assay for proANP measures higher concentrations than the standard MR-proANP assay, suggesting covalent modification, but both assays have similar clinical performance in detecting LV dysfunction and predicting mortality.
BACKGROUND: The N-terminal fragment of cardiac-derived pro-B-type natriuretic peptide is a glycosylated polypeptide. It is unknown whether N-terminal pro-atrial natriuretic peptide (proANP) fragments are also covalently modified. We therefore evaluated the clinical performance of 2 distinctly different proANP assays on clinical outcome. METHODS: We examined 474 elderly patients with symptoms of heart failure presenting in a primary healthcare setting. Samples were analyzed with an automated immunoluminometric midregion proANP (MR-proANP) assay and a new processing-independent assay (PIA) developed in our laboratory. The results were compared with Bland-Altman plots, and clinical performance was assessed by generating ROC curves for different clinical outcomes. RESULTS: Despite linear regression results indicating a good correlation (r = 0.85; P < 0.0001), the PIA measured considerably more proANP than the MR-proANP assay (mean difference, 663 pmol/L; SD, 478 pmol/L). In contrast, the clinical performances of the 2 assays [as assessed by the area under the ROC curve (AUC)] in detecting left ventricular dysfunction were similar [proANP PIA, 0.71 (95% CI, 0.63-0.79); MR-proANP assay, 0.74 (95% CI, 0.66-0.81); P = 0.32]. The prognostic ability to report cardiovascular mortality during a 10-year follow-up revealed AUC values of 0.66 (95% CI, 0.60-0.71) for the proANP PIA and 0.69 (95% CI, 0.63-0.74) for the MR-proANP assay (P = 0.08, for comparing the 2 assays). CONCLUSIONS: Our data suggest that N-terminal proANP fragments in patient plasma differ from the calibrator peptides used but that the difference does not affect ROC curves in an elderly cohort of patients with mild to moderate heart failure. We suggest that human N-terminal proANP fragments can be covalently modified.
No takes yet. Share an insight, caveat, or question.
Hunter et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: