Why the study?
Does the HEM-780REL automatic blood pressure monitor with Easy Wrap Cuff accurately measure blood pressure compared to a mercury standard in adults over 30 years?
Does the HEM-780REL automatic blood pressure monitor with Easy Wrap Cuff accurately measure blood pressure compared to a mercury standard in adults over 30 years?
The HEM-780REL automatic blood pressure monitor with Easy Wrap Cuff is accurate for self-measurement of blood pressure according to the European Society of Hypertension International Protocol.
Answers are grounded in this paper and cite their sources.
Supports HEM-780REL accuracy for home monitoring; leaves open need for outcome trials before routine adoption.
OBJECTIVE: We tested the accuracy of the HEM-780REL automatic blood pressure monitor with Easy Wrap Cuff. METHODS: We used the International Protocol for validation of blood pressure measuring devices developed by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Thirty-three adults over the age of 30 years participated to have 11 total participants in each of the three required blood pressure ranges for systolic and diastolic blood pressure. Sequential blood pressure readings were taken independently by trained observers using a mercury standard with appropriate size cuff. A third observer performed measurements with the test device. Analyses were performed according to International Protocol specifications for the 99 pairs of measurements. The device was given a pass/fail recommendation based on bands of accuracy compared with the mercury standard (within 5, 10, or 15 mmHg), as well as number of readings per participant within 5 mmHg. RESULTS: The mean blood pressure difference was 0.52+/-7.7 mmHg for systolic blood pressure and 0.39+/-4.7 mmHg for diastolic blood pressure. Twenty-four out of 33 participants had two out of three readings within 5 mmHg of the mercury standard for systolic blood pressure. Twenty-seven out of 33 participants had two out of three readings within 5 mmHg of the mercury standard for diastolic blood pressure. The device received a passing grade both for accuracy of individual measurements and for accuracy for individuals. CONCLUSION: The HEM-780REL with Easy Wrap Cuff performs accurately according to the standards of the International Protocol.
No takes yet. Share an insight, caveat, or question.
Viera et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: