Why the study?
MED625FLX and TPU95A could be appropriate candidates for cardiac 3D surgical guides during radiofrequency ablation, but their thermal properties during ablation required analysis.
Do 3D-printed biomaterials (MED625FLX and TPU95A) maintain safe thermal properties and structural integrity during unipolar and bipolar radiofrequency ablation?
Do 3D-printed biomaterials (MED625FLX and TPU95A) maintain safe thermal properties and structural integrity during unipolar and bipolar radiofrequency ablation?
The 2.5 mm MED625FLX biomaterial is thermally and structurally suitable for 3D surgical guides during bipolar radiofrequency ablation, but not unipolar ablation.
Answers are grounded in this paper and cite their sources.
Biomaterials may suit RFA guides; leaves open clinical translation pending validation.
Background: Due to their mechanical properties, the MED625FLX and TPU95A could be appropriate candidates for cardiac 3D surgical guide use during radiofrequency ablation (RFA) treatment. Methods: RFA aims to destroy the heart tissue, which cause arrhythmias, by applying a radiofrequency (RF) energy at critical temperature above +50.0°C, where the thermal damage is considered not reversible. This study aims to analyze the biomaterials thermal properties with different thicknesses, by testing the response to bipolar and unipolar RFA on porcine muscle samples (PMS), expressed in temperature. For the materials evaluation, the tissue temperature during RFA applications was recorded, firstly without (control) and after with the biomaterials in position. The biomaterials were considered suitable for the RFA treatment if: (1) the PMS temperatures with the samples were not statistically different compared with the control; (2) the temperatures never reached the threshold; (3) no geometrical changes after RFA were observed. Results: Based on these criteria, none of the tested biomaterials resulted appropriate for unipolar RFA and the TPU95A failed almost all thermal tests also with the bipolar RFA. The 1.0 mm MED625FLX was modified by bipolar RFA in shape, losing its function. Instead, the 2.5 mm MED625FLX was considered suitable for bipolar RFA catheter use only. Conclusions: The 2.5 mm MED625FLX could be used, in the design of surgical guides for RFA bipolar catheter only, because of mechanical, geometrical, and thermal properties. None of biomaterials tested are appropriate for unipolar ablation catheter because of temperature concerns. Further investigations for clinical use are eagerly awaited.
No takes yet. Share an insight, caveat, or question.
Cappello et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: