Key result
The real-time stimulation and recording system successfully detected His-bundle activations in 18 ± 6.8% of the 64 electrodes used during ventricular fibrillation in explanted rabbit hearts.
Why the study?
His-bundle pacing is increasingly relevant for non-reversible bradyarrhythmia, but tools to identify the His bundle remain limited, and the causal effects of selective His-bundle pacing during ventricular fibrillation are unknown.
A novel real-time stimulation and recording system can successfully identify and selectively pace the His-bundle during both sinus rhythm and ventricular fibrillation in an ex vivo rabbit model.
May aid real-time His-bundle localization in pacing; leaves open clinical utility pending prospective validation.
BACKGROUND: The His-Purkinje (HP) system provides a pathway for the time-synchronous contraction of the heart. His bundle (HB) of the HP system is gaining relevance as a pacing site for treating non-reversible bradyarrhythmia despite limited availability of tools to identify the HB. In this paper, we describe a real-time stimulation and recording system (rt-SRS) to investigate using multi-electrode techniques to identify and selectively pace the HB. The rt-SRS can not only be used in sinus rhythm, but also during ventricular fibrillation (VF). The rt-SRS will also help investigate the so far unknown causal effects of selectively pacing the HB during VF. METHODS: The rt-SRS consists of preamplifiers, data acquisition cards interfaced with a real-time controller, a current source, and current routing switches on a remote computer, which may be interrupted to stimulate using a host machine. The remote computer hosts a series of algorithms designed to aid in identifying electrodes directly over the HB, to accurately detect activation rates without over-picking, and to deliver stimulation pulses. The performance of the rt-SRS was demonstrated in seven isolated, perfused rabbit hearts. RESULTS: The rt-SRS can visualize up to 96 channels of raw data, and spatial derivative data at 6.25-kHz sampling rate with an input-referred noise of 100 µV. The rt-SRS can send up to ± 150 V of stimuli pulses to any of the 96 channels. In the rabbit experiments, HB activations were detected in 18 ± 6.8% of the 64 electrodes used during VF. CONCLUSIONS: The rt-SRS is capable of measuring and responding to cardiac electrophysiological phenomena in real-time with precisely timed and placed electrical stimuli. This rt-SRS was shown to be an effective research tool by successfully detecting and quantifying HB activations and delivering stimulation pulses to selected electrodes in real-time.
No takes yet. Share an insight, caveat, or question.
Shah et al. (2020) studied Ventricular fibrillation (n=7). Real-time stimulation and recording system (rt-SRS) was evaluated on Detection of His-bundle activations during ventricular fibrillation. The real-time stimulation and recording system successfully detected His-bundle activations in 18 ± 6.8% of the 64 electrodes used during ventricular fibrillation in explanted rabbit hearts.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: