Why the study?
Does the measurement of plasma TXB2 and beta TG help detect or differentiate myocardial ischemia from infarction in patients admitted with chest pain?
Population
98 patients admitted to a coronary care unit with chest pain
Comparison
Serial measurement of plasma thromboxane B2 and… vs Patients with noncardiac chest pain
Design
Cohort
Authors
Loading...
Plasma TXB2 and beta TG lack diagnostic utility in acute chest pain; hypothesis-generating for platelet activation biomarkers in ACS.
Does the measurement of plasma TXB2 and beta TG help detect or differentiate myocardial ischemia from infarction in patients admitted with chest pain?
The measurement of beta TG and TXB2 lacks clinical value in detecting or differentiating myocardial ischemia from infarction in patients presenting with chest pain.
Boer et al. (1982) studied this question.