Why the study?
The degree of ICA stenosis by NASCET criteria does not accurately reflect distal flow compromise, which is also influenced by tandem stenosis and collaterals.
Does non-invasive laser speckle flowgraphy (LSFG) correlate with the degree of stenosis and quantify end-organ perfusion in patients with symptomatic carotid stenosis?
Does non-invasive laser speckle flowgraphy (LSFG) correlate with the degree of stenosis and quantify end-organ perfusion in patients with symptomatic carotid stenosis?
LSFG can non-invasively quantify end-organ blood flow distal to the ICA origin and may help determine if proximal carotid stenosis is symptomatic.
Answers are grounded in this paper and cite their sources.
Ocular LSFG may refine distal ICA flow assessment beyond NASCET; leaves open its clinical utility in carotid disease management.
Background and Purpose The degree of internal carotid artery (ICA) stenosis determined by criteria from the North American Symptomatic Carotid Endarterectomy Trial (NASCET) is not the most accurate index to assess distal flow compromise. Distal ICA perfusion is also determined by factors such as tandem carotid stenosis and collateral circulation. Quantification of end-organ ocular perfusion using non-invasive laser speckle flowgraphy (LSFG) may provide insights into distal ICA flow. This study prospectively assessed the degree of ICA flow using LSFG. Methods Eighteen patients with symptomatic carotid stenosis underwent LSFG evaluation. LSFG was used to extract ocular blood flow metrics recorded simultaneously in the retina, choroid, and optic nerve head. The following ocular flow parameters were measured with LSFG: mean blur rate (MBR), flow acceleration index (FAI), and rising rate (RR). Syngo iFlow perfusion imaging was used to objectively quantify contrast flow in the ICA and brain parenchyma during digital subtraction angiography. Time to peak (TTP) and contrast delay were extracted from seven different regions of interest (ROIs). Results MBR, FAI, and RR were correlated with NASCET degree of stenosis. FAI and RR also improved after stenting. TTP improved after stenting in three ROIs. A moderate negative correlation was observed between FAI and contrast delay. Conclusions LSFG non-invasively quantifies end-organ blood flow distal to the ICA origin. LSFG metrics have the potential to quantify end-organ perfusion and determine if a proximal carotid stenosis is symptomatic.
No takes yet. Share an insight, caveat, or question.
Jones et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: