Key result
The FlexNav delivery system significantly reduced the rate of moderate-to-severe paravalvular leak compared to the first-generation delivery system (4.5% vs 28.6%, p=0.03) during transcatheter aortic valve replacement.
Why the study?
Technological advancements in transcatheter heart valve platforms are essential to achieve high efficacy and safety, prompting evaluation of the new Portico FlexNav delivery system versus the first-generation device.
Does the FlexNav delivery system improve in-hospital procedural outcomes and safety compared to the first-generation delivery system in patients undergoing Portico TAVR?
Observational (n=50)
No
Does the FlexNav delivery system improve in-hospital procedural outcomes and safety compared to the first-generation delivery system in patients undergoing Portico TAVR?
The new FlexNav delivery system for the Portico TAVR valve is associated with a significant reduction in moderate-to-severe paravalvular leak compared to the first-generation system.
Introduction: Technological advancements in transcatheter heart valve platforms are essential in order to achieve high standards of efficacy and safety in transcatheter aortic valve replacement (TAVR).Aim: To evaluate the performance of the new version of the Portico valve delivery system (FlexNav) as compared to the first-generation device.Material and methods: In this single-center, observational study consecutive patients undergoing Portico valve implantation with the new FlexNav delivery system (DS) were compared with patients treated with the first-generation delivery system (1 st gen DS).In-hospital outcomes were self-adjudicated according to the Valve Academic Research Consortium-3 definition.Results: Fifty patients were included in this study; 22 were treated with the FlexNav DS and the remaining patients with the 1 st gen DS.Clinical characteristics were similar between groups, except for older age (82.6 3.6 vs. 80.7 3.8; p = 0.07) and higher prevalence of female gender (68.2% vs. 39.3%;p = 0.04) in the FlexNav DS group as compared to the 1 st gen DS group, respectively.We observed similar rates of procedural success but higher rate of moderate-to-severe paravalvular leak in the 1 st gen DS as compared to FlexNav DS group (28.6% vs. 4.6%; p = 0.03); major vascular complications were reduced, although not significantly, in the FlexNav DS as compared to the 1 st gen DS group (4.5% vs. 10.7%;p = 0.64).Conclusions: Our data suggest that the FlexNav DS, thanks to its lower profile and enhanced stability during valve deployment, might be associated with reduced rates of vascular complications and moderate to severe paravalvular leak, thus improving procedural results.
No takes yet. Share an insight, caveat, or question.
Rigattieri et al. (2023) conducted an observational in Severe aortic stenosis (n=50). FlexNav delivery system vs. First-generation delivery system was evaluated on Moderate-to-severe paravalvular leak (p=0.03). The FlexNav delivery system significantly reduced the rate of moderate-to-severe paravalvular leak compared to the first-generation delivery system (4.5% vs 28.6%, p=0.03) during transcatheter aortic valve replacement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: