Key result
Low-workload exercise PAWP outperforms passive leg raise for diagnosing HFpEF with an AUC of ~0.85.
Why the study?
Provocative tests during right heart catheterization can unmask occult HFpEF, but the diagnostic performance of PAWP during passive leg raise and supine low-workload exercise needed exploration.
Does pulmonary artery wedge pressure measured during passive leg raise (PAWP_PLR) and low-workload supine exercise (PAWP_EX1) accurately diagnose or exclude occult HFpEF compared to maximal symptom-limited exercise right heart catheterization in patients with unexplained dyspnea and normal resting filling pressures?
Cohort (n=166)
Yes
Does pulmonary artery wedge pressure measured during passive leg raise (PAWP_PLR) and low-workload supine exercise (PAWP_EX1) accurately diagnose or exclude occult HFpEF compared to maximal symptom-limited exercise right heart catheterization in patients with unexplained dyspnea and normal resting filling pressures?
Answers are grounded in this paper and cite their sources.
Passive leg raise and low-workload supine exercise during right heart catheterization have high specificity for ruling in occult HFpEF in patients with unexplained dyspnea, but they have poor sensitivity for ruling it out, with low-workload exercise demonstrating superior overall diagnostic accuracy (AUC 0.85 vs 0.67).
Background Provocative tests during right heart catheterization (RHC) can unmask occult heart failure with preserved ejection fraction (HFpEF). We sought to explore the performance of pulmonary artery wedge pressure (PAWP) during both passive leg raise (PLR) and supine low-workload exercise ( EX1 ; ie, the first step of a step-incremental exercise) to diagnose or exclude HFpEF. Methods In this 2-center international cohort study, we sought to evaluate the diagnostic performance of PAWP PLR and PAWP EX1 in consecutive patients with unexplained dyspnea and PAWP at rest ≤ 15 mmHg who underwent a symptom-limited exercise supine RHC. Results We included 166 patients; more than 50% had an intermediate HFpEF probability; 75% eventually classified as HFpEF after exercise RHC. The area under the curve was 0.67 (0.58–0.76) for PAWP PLR and 0.85 (0.79-0.92) for PAWP EX1 . Only PAWP PLR < 4 mmHg certainly excluded HFpEF, with higher PAWP PLR thresholds (eg, < 11 mmHg) being associated with lower sensitivity (80%) and low negative predictive value (34%). PAWP PLR ≥ 21 and ≥ 19 mmHg identified HFpEF with a specificity of 100% and 98%, and a positive predictive value of 100% and 96%, respectively. During a low-workload exercise, PAWP EX1 < 9 mmHg ruled out HFpEF with 100% sensitivity and negative predictive value. PAWP EX1 > 25 mmHg was 100% specific for HFpEF, while PAWP EX1 values between 21 and 25 showed acceptable specificity (90%–95%) and positive predictive value (95%–96%). Conclusions PLR and low-workload supine exercise may reduce the hemodynamic zone of uncertainty for the diagnosis of HFpEF. Both may be useful for the ruling-in of this syndrome, although they are less efficacious for ruling-out HFpEF.
No takes yet. Share an insight, caveat, or question.
Baratto et al. (2025) conducted a cohort in Unexplained dyspnea with suspected occult heart failure with preserved ejection fraction (HFpEF) (n=166). Pulmonary artery wedge pressure during passive leg raise (PAWP_PLR) and supine low-workload exercise (PAWP_EX1) vs. Symptom-limited peak exercise RHC (HFpEF defined as peak PAWP >= 25 mmHg and/or PAWP/CO slope > 2 mmHg/L/min) was evaluated on Diagnostic performance (AUC) for identifying HFpEF (peak exercise PAWP >= 25 mmHg and/or PAWP/CO slope > 2 mmHg/L/min) (AUC 0.85 for PAWP_EX1; AUC 0.67 for PAWP_PLR, 95% CI 0.79-0.92). Supine low-workload exercise PAWP showed superior diagnostic accuracy over passive leg raise PAWP for diagnosing occult HFpEF, with both maneuvers better at ruling in than ruling out disease.
Synapse has enriched 10 related papers. Consider them for comparative context: