Why the study?
Automated determination of photoplethysmography peaks and valleys during a Valsalva maneuver is limited in significant arrhythmias such as atrial fibrillation and premature ventricular complexes.
Does root mean square (RMS) analysis of photoplethysmography signals correlate with peak-to-valley amplitude analysis for assessing cardiac filling pressure during a Valsalva maneuver in patients with and without arrhythmias?
Does root mean square (RMS) analysis of photoplethysmography signals correlate with peak-to-valley amplitude analysis for assessing cardiac filling pressure during a Valsalva maneuver in patients with and without arrhythmias?
RMS analysis of photoplethysmography signals during a Valsalva maneuver provides a robust, automated alternative to peak-valley amplitude for assessing cardiac filling pressure, particularly in patients with arrhythmias.
Answers are grounded in this paper and cite their sources.
RMS-based PPG Valsalva analysis correlates highly with amplitude method in arrhythmias; supports validation as automated filling pressure tool in HF.
OBJECTIVE: We previously showed that the change in amplitude of a finger photoplethysmography waveform during the Valsalva maneuver reflects cardiac filling pressure. However, the automated determination of peaks and valleys to calculate amplitude is limited in significant arrhythmias such as atrial fibrillation and premature ventricular complexes, which are common in heart failure. The purpose of this study was to assess the change in size of the waveform by calculating the change in root mean square (RMS) of the signal, thereby utilizing the entire cardiac cycle, and to compare it to change in size of peak-to-valley amplitude. APPROACH: We compared the two approaches in signals obtained from participants of a prior study who were tested prior to a clinically indicated cardiac catheterization. Correlation between the two methods was assessed in cases without, and then with, significant arrhythmias including atrial fibrillation or premature ventricular complexes. MAIN RESULTS: Calculations from the two methods of peak-valley amplitude and RMS were highly correlated with each other in signals without (0.99, p < 0.0001, n = 252) and with significant arrhythmias (0.90, p < 0.0001, n = 34). SIGNIFICANCE: RMS analysis of photoplethysmography signal size during the Valsalva maneuver is highly correlated with the method of analyzing changes in peak-valley amplitude, but does not rely on identifying peaks and valleys. The RMS method may be a more robust automated method of assessing cardiac filling pressure in patients with significant arrhythmias.
No takes yet. Share an insight, caveat, or question.
Silber et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: