Why the study?
Does contrast transcranial Doppler ultrasound accurately detect cardiac right-to-left shunts compared to transesophageal echocardiography?
Does contrast transcranial Doppler ultrasound accurately detect cardiac right-to-left shunts compared to transesophageal echocardiography?
Contrast transcranial Doppler ultrasound performed twice with saline or galactose-based contrast is a sensitive method for identifying cardiac right-to-left shunts compared to transesophageal echocardiography.
Answers are grounded in this paper and cite their sources.
TCD may support sensitive shunt detection versus TEE; leaves open the need for prospective validation before clinical adoption.
BACKGROUND AND PURPOSE: Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Furthermore, we assessed the side distribution of thus provoked artificial cardiac emboli. METHODS: Fifty-four patients were investigated by TEE and by bilateral TCD of the middle cerebral artery. The following protocol was performed twice: injection of 9 mL of agitated saline without Valsalva maneuver, injection of 9 mL of agitated saline with Valsalva maneuver, injection of 5 mL of a commercial galactose-based contrast agent without Valsalva maneuver, and injection of 5 mL of the galactose-based contrast agent with Valsalva maneuver. RESULTS: In 18 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt positive). Twenty-nine patients were negative in both investigations, 1 was positive on TEE and negative on TCD, and 6 patients were only positive on TCD. Both bilateral and repeated recordings increased the sensitivity of contrast TCD. There was a symmetrical distribution of microembolic signals in the right and left middle cerebral artery. CONCLUSIONS: TCD performed twice and with the use of saline or a galactose-based contrast agent is a sensitive method in the identification of cardiac right-to-left shunts also identified by TEE. The cardiac microemboli in this study did not show any side preference for one of the middle cerebral arteries.
No takes yet. Share an insight, caveat, or question.
Droste et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: