Answers are grounded in this paper and cite their sources.
A compact mid-wavelength infrared zoom camera with a zoom range of 20:1 and automatic athermalization has been developed. The moving groups for a wide zoom range are only two lens groups and the loci of zoom are very simple, which allows easy access of optom- echanical and electromechanical design. In addition, the microscanning technique was introduced to improve resolving power. We acquired in- creased resolving power of 7.6 cycles/mrad, superior to the original Ny- quist frequency of 4.5 cycles/mrad. The temperature range, being 230 to 155°C, in which the camera is to operate, is rather wide. The minimum resolvable temperature difference of the zoom camera is 0.3°C at 6 cycles/mrad.
No takes yet. Share an insight, caveat, or question.
Hyun Sook Kim (2002) studied this question.