Key result
Three-dimensional printing of the tricuspid valve from 3DTTE data is feasible and highly accurate, with measurements highly correlated to the original 3D data.
Why the study?
Is it feasible and accurate to generate 3D patient-specific models of the tricuspid valve from transthoracic 3D echocardiography data?
Observational (n=5)
Is it feasible and accurate to generate 3D patient-specific models of the tricuspid valve from transthoracic 3D echocardiography data?
Answers are grounded in this paper and cite their sources.
3D printing of the tricuspid valve from transthoracic 3D echocardiography is feasible and highly accurate, potentially aiding in surgical planning and decision-making.
AIMS: To explore the feasibility of using transthoracic 3D echocardiography (3DTTE) data to generate 3D patient-specific models of tricuspid valve (TV). METHODS AND RESULTS: Multi-beat 3D data sets of the TV (32 vol/s) were acquired in five subjects with various TV morphologies from the apical approach and analysed offline with custom-made software. Coordinates representing the annulus and the leaflets were imported into MeshLab (Visual Computing Lab ISTICNR) to develop solid models to be converted to stereolithographic file format and 3D print. Measurements of the TV annulus antero-posterior (AP) and medio-lateral (ML) diameters, perimeter (P), and TV tenting height (H) and volume (V) obtained from the 3D echo data set were compared with those performed on the 3D models using a caliper, a syringe and a millimeter tape. Antero-posterior (4.2 ± 0.2 cm vs. 4.2 ± 0 cm), ML (3.7 ± 0.2 cm vs. 3.6 ± 0.1 cm), P (12.6 ± 0.2 cm vs. 12.7 ± 0.1 cm), H (11.2 ± 2.1 mm vs. 10.8 ± 2.1 mm) and V (3.0 ± 0.6 ml vs. 2.8 ± 1.4 ml) were similar (P = NS for all) when measured on the 3D data set and the printed model. The two sets of measurements were highly correlated (r = 0.991). The mean absolute error (2D - 3D) for AP, ML, P and tenting H was 0.7 ± 0.3 mm, indicating accuracy of the 3D model of <1 mm. CONCLUSION: Three-dimensional printing of the TV from 3DTTE data is feasible with highly conserved fidelity. This technique has the potential for rapid integration into clinical practice to assist with decision-making, surgical planning, and teaching.
No takes yet. Share an insight, caveat, or question.
Muraru et al. (2016) conducted an observational in Tricuspid valve morphology (n=5). 3D printed models of the tricuspid valve vs. 3D echocardiography data set was evaluated on Measurements of tricuspid valve annulus diameters, perimeter, tenting height, and volume (r = 0.991, p=NS). Three-dimensional printing of the tricuspid valve from 3DTTE data is feasible and highly accurate, with measurements highly correlated to the original 3D data.
Synapse has enriched 10 related papers. Consider them for comparative context: