Why the study?
Does transesophageal Doppler evaluation of coronary sinus flow correlate with LAD flow for assessing coronary flow reserve in patients with and without LAD stenosis?
Does transesophageal Doppler evaluation of coronary sinus flow correlate with LAD flow for assessing coronary flow reserve in patients with and without LAD stenosis?
Transesophageal Doppler evaluation of both the coronary sinus and LAD are feasible and correlate well for the noninvasive assessment of coronary flow reserve.
May support noninvasive CFR assessment; leaves open validation in prospective trials before clinical adoption.
BACKGROUND: Currently used methods for assessment of coronary flow reserve are invasive and require extensive laboratory equipment. Recently, noninvasive assessment of coronary flow reserve by transesophageal Doppler evaluation of coronary sinus (CS) or left anterior descending coronary artery (LAD) flow has been proposed. Direct comparison between these two techniques is lacking. METHODS: Doppler recordings of CS and LAD flow velocity were obtained before and after 0.6 mg/kg/5 min dipyridamole in 16 patients with significant stenosis of the LAD (Group A) and in 14 control patients (Group B). Flow recordings and all measurements were performed in a blinded manner. For assessment of coronary flow reserve, Doppler measurements after dipyridamole were divided by the respective baseline values. RESULTS: Doppler studies of the CS and LAD were feasible in 30 of 30 (100%) and 23 of 30 (71%) patients, respectively. Analyzing the maximum flow velocities, coronary flow reserve in Groups A and B was 1.18 +/- 0.28 and 1.68 +/- 0.53 with CS recordings and 1.78 +/- 0.83 and 2.51 +/- 0.76 with LAD recordings, respectively. Analyzing the velocity time integrals, coronary flow reserve in Groups A and B was 1.53 +/- 0.68 and 2.59 +/- 0.74 with CS recordings and 1.77 +/- 0.38 and 2.68 +/- 0.93 with LAD recordings, respectively. Correlation between LAD and CS recordings was 0.69 (p < 0.001), when coronary flow reserve was calculated from the velocity time integral and 0.68 (p < 0.001) when the maximum flow velocities were used. CONCLUSION: Both transesophageal Doppler techniques might be useful for noninvasive assessment of coronary flow reserve.
No takes yet. Share an insight, caveat, or question.
Mundigler et al. (1997) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: