Why the study?
Does single, total paracentesis alter hemodynamics and right atrial size in patients with tense ascites?
Does single, total paracentesis alter hemodynamics and right atrial size in patients with tense ascites?
Total paracentesis for tense ascites causes an initial increase in cardiac output followed by delayed relative hypovolemia, suggesting a need for plasma expansion 3-12 hours post-procedure.
Paracentesis was associated with delayed relative hypovolemia; leaves open whether timed plasma expansion improves outcomes in tense ascites.
Hemodynamic changes induced by a single, total paracentesis were evaluated in 21 patients with tense ascites from whom 4 to 16 L of ascites were drained over 2 to 8 hr with no serious complications. At 60 min, compared to baseline, there was an increase in cardiac output (7.7 +/- 0.5 to 8.5 +/- 0.6 L/min, p less than 0.02) and a tendency for right atrial pressure to decrease (9.3 +/- 0.8 to 7.50 +/- 0.8 mm Hg, NS), with no change in pulmonary capillary wedge pressure (10.9 +/- 0.9 to 10.7 +/- 0.9 mm Hg). Between 3 and 12 hr later, there was a drop in right atrial pressure, pulmonary capillary wedge pressure and cardiac output to 5.6 +/- 0.6 (p less than 0.02), 7.2 +/- 0.8 mm Hg (p less than 0.002) and 7.2 +/- 0.6 L/min (NS) respectively, indicative of the development of relative hypovolemia and suggesting that therapeutic plasma expansion is appropriate at this time. Two-dimensional echocardiography before paracentesis (n = 8) showed a reduction in the right to left atrium area ratio as compared with values in patients with minimal ascites (0.54 +/- 0.04 vs 0.82 +/- 0.02, p less than 0.0001). This technique may help in identifying patients with right atrial compression caused by tense ascites.
No takes yet. Share an insight, caveat, or question.
Panos et al. (1990) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: