Key result
Initial H-FABP measurement for diagnosing myocardial infarction had a sensitivity of 80.9% and specificity of 19.2%, while third-hour measurement had a sensitivity of 46.7% and specificity of 80.2%.
Why the study?
Does serial measurement of H-FABP improve the rapid diagnosis of acute coronary syndromes in patients presenting to the emergency department with chest pain?
Observational (n=183)
Does serial measurement of H-FABP improve the rapid diagnosis of acute coronary syndromes in patients presenting to the emergency department with chest pain?
Serial H-FABP measurement is superior to myoglobin for diagnosing MI, but its negative predictive value at 3 hours is insufficient to safely shorten ED observation times.
H-FABP's poor specificity initially and sensitivity later limit rapid MI diagnosis; leaves open adjunctive value versus troponin in ED chest pain.
Introduction We aimed to investigate the diagnostic accuracy of heart-type fatty acid binding protein (H-FABP) at admission and the third and sixth hour after admission in patients presenting to the emergency department (ED) with chest pain or equivalent symptoms. Methods This prospective study was performed over two months in the ED. Patients presenting with ischaemic-type chest pain or other symptoms suggestive of myocardial ischaemia were included in the study. A bedside, point-of-care, quantitative H-FABP level was measured. If the initial electrocardiography (ECG) was non-diagnostic, the patients were observed for six hours. During the observation period, serial H-FABP measurements were obtained at admission, the third hour and the sixth hour; serial measurements of total creatine kinase (CK), CK-MB, troponin I and myoglobin were recorded at admission and the sixth hour. Results A total of 183 patients were included in the study. Initial H-FABP was measured in a joint group of ST segment elevation myocardial infarction (STEMI) and non ST segment elevation myocardial infarction (NSTEMI) patients, with a sensitivity of 80.9%, specificity of 19.2%, positive predictive value (PPV) of 23% and negative predictive value (NPV) of 77.1%. The third-hour H-FABP was measured in the NSTEMI group, with a sensitivity of 46.7%, specificity of 80.2%, PPV of 42.4% and NPV of 82.6%. The sixth-hour H-FABP had a sensitivity of 33.3%, specificity of 73.9%, PPV of 24.2% and NPV of 81.5%. Conclusion H-FABP is superior to myoglobin for diagnosing myocardial infarction in a joint group of STEMI and NSTEMI patients. The third-hour NPV value for H-FABP indicates that, for safety considerations, the cardiac observation time should not be shortened. (Hong Kong j.emerg.med. 2014;21:213-221)
No takes yet. Share an insight, caveat, or question.
Limon et al. (2014) conducted an observational in Acute Coronary Syndromes (n=183). Heart-type fatty acid binding protein (H-FABP) measurement vs. Myoglobin was evaluated on Diagnosis of myocardial infarction. Initial H-FABP measurement for diagnosing myocardial infarction had a sensitivity of 80.9% and specificity of 19.2%, while third-hour measurement had a sensitivity of 46.7% and specificity of 80.2%.