Why the study?
What are the plasma bupivacaine concentrations in children following caudal epidural analgesia with 3 mg/kg of bupivacaine 0.25%?
What are the plasma bupivacaine concentrations in children following caudal epidural analgesia with 3 mg/kg of bupivacaine 0.25%?
Caudal epidural analgesia with 3 mg/kg of bupivacaine 0.25% in children produces plasma concentrations safely below projected toxic levels.
Answers are grounded in this paper and cite their sources.
May support safe caudal bupivacaine dosing in children; leaves open need for randomized confirmation of sampling-site effects and toxicity thresholds.
Plasma bupivacaine concentrations were measured in 45 children, whose ages ranged from 4 months to 12 years, following administration of caudal epidural analgesia. Using 3 mg/kg of bupivacaine 0.25%, mean blood levels of 1.2-1.4 microgram/ml were reached, which are well within the limits of projected toxic levels. Simultaneous arterial and venous sampling showed a small but significant difference between these two sampling sites fo the first fifteen minutes.
No takes yet. Share an insight, caveat, or question.
Eyres et al. (1983) studied this question.