Why the study?
Patients with bicuspid valves represent a challenging anatomical subgroup for TAVI, prompting evaluation of the repositionable and retrievable Lotus Valve System in this cohort.
Does TAVI with the Lotus Valve System improve clinical and echocardiographic outcomes in patients with bicuspid aortic valve stenosis?
Does TAVI with the Lotus Valve System improve clinical and echocardiographic outcomes in patients with bicuspid aortic valve stenosis?
The repositionable Lotus Valve System demonstrated 100% procedural success and significant improvements in hemodynamics with acceptable safety in a small cohort of patients with bicuspid aortic valve stenosis.
Hypothesis-generating for Lotus TAVI in bicuspid AS; prospective randomized trials needed before practice change.
Aims Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post‐market registry. Methods and Results The prospective, open‐label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve‐in‐valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30‐day follow‐up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm2 to 1.7 ± 0.4 cm2 (P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM‐naïve patients was 22.2% (6/27). Conclusions Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspid aortic valves using the repositionable Lotus Valve.
No takes yet. Share an insight, caveat, or question.
Blackman et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: