Key result
A mini-fluid challenge test with 100 mL of colloid predicted stroke volume fluid responsiveness with an AUROC of 0.90, significantly outperforming pulse pressure variation and stroke volume variation.
Why the study?
It was unclear whether a mini-fluid challenge test is more reliable than dynamic fluid variables for predicting stroke volume and arterial pressure fluid responsiveness during prone spine surgery with low-tidal-volume ventilation.
Does a mini-fluid challenge test predict stroke volume and arterial pressure fluid responsiveness better than dynamic fluid variables in patients undergoing spine surgery in the prone position?
Observational (n=50)
No
Does a mini-fluid challenge test predict stroke volume and arterial pressure fluid responsiveness better than dynamic fluid variables in patients undergoing spine surgery in the prone position?
Effect estimate: AUROC 0.90 (95% CI 0.82-0.99)
Absolute Event Rate: 0.9% vs 0.71%
p-value: p=0.01
A mini-fluid challenge test using 100 mL of colloid is a reliable predictor of stroke volume and arterial pressure fluid responsiveness during spine surgery in the prone position.
Mini-fluid challenge may better predict responsiveness than dynamic indices in prone low-TV surgery; leaves open RCT validation before practice change.
The study was designed to verify if mini-fluid challenge test is more reliable than dynamic fluid variables in predicting stroke volume (SV) and arterial pressure fluid responsiveness during spine surgery in prone position with low-tidal-volume ventilation.Fifty patients undergoing spine surgery in prone position were included. Fluid challenge with 500 mL of colloid over 15 minutes was given. Changes in SV and systolic blood pressure (SBP) after initial 100 mL were compared with SV, pulse pressure variation (PPV), SV variation (SVV), plethysmographic variability index (PVI), and dynamic arterial elastance (Eadyn) in predicting SV or arterial pressure fluid responsiveness (15% increase or greater).An increase in SV of 5% or more after 100 mL predicted SV fluid responsiveness with area under the receiver operating curve (AUROC) of 0.90 (95% confidence interval [CI], 0.82 to 0.99), which was significantly higher than that of PPV (0.71 [95% CI, 0.57 to 0.86]; P = .01), and SVV (0.72 [95% CI, 0.57 to 0.87]; P = .03). A more than 4% increase in SBP after 100 mL predicted arterial pressure fluid responsiveness with AUROC of 0.86 (95% CI, 0.71-1.00), which was significantly higher than that of Eadyn (0.52 [95% CI, 0.33 to 0.71]; P = .01).Changes in SV and SBP after 100 mL of colloid predicted SV and arterial pressure fluid responsiveness, respectively, during spine surgery in prone position with low-tidal-volume ventilation.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2020) conducted an observational in Spine surgery in prone position (n=50). Mini-fluid challenge test vs. Dynamic fluid variables (PPV, SVV, PVI) was evaluated on Prediction of stroke volume fluid responsiveness (≥15% increase in SV) (AUROC 0.90, 95% CI 0.82-0.99, p=0.01). A mini-fluid challenge test with 100 mL of colloid predicted stroke volume fluid responsiveness with an AUROC of 0.90, significantly outperforming pulse pressure variation and stroke volume variation.