A design study has been made of a pulse stretcher to increase the duty factor of the 300 MeV electron accelerator of the Saskatchewan Accelerator Laboratory. The design was constrained by the desire to house the pulse stretcher within the existing accelerator building and to make maximal use of existing beam transport lines. The pulse stretcher ring consists of two 180/sup 0/ bend regions connected by achromatic straight sections. The overall length is 50.49 m and the width is 6.64m. The modes of injection and extraction will be available. In the first mode a shortened linac pulse of 300 ns duration will be injected during a single turn directly into the closed orbit of the pulse stretcher. A second mode of injection/extraction involves use of a longer linac pulse. The basic geometry of the PSR is dictated by the dimensions of the accelerator vault and access room.
No takes yet. Share an insight, caveat, or question.
Bergstrom et al. (1983) studied this question.