Key result
Orthotopic implantation of 19-mm bileaflet mechanical aortic valves in adult sheep was technically feasible, with 100% survival to 150 days and no clinically significant thrombus or paravalvular leaks.
Why the study?
Is it technically feasible to orthotopically implant mechanical aortic valves in adult domestic sheep to create a reproducible preclinical model?
Is it technically feasible to orthotopically implant mechanical aortic valves in adult domestic sheep to create a reproducible preclinical model?
Orthotopic implantation of mechanical aortic valves in adult sheep is technically feasible and reproducible, providing a valuable preclinical model for evaluating new valve designs.
Answers are grounded in this paper and cite their sources.
Establishes reproducible sheep model for mechanical aortic valve testing; leaves open validation for novel designs and clinical translation.
This study was intended to develop a technically feasible and reproducible model for chronic hemodynamic and mechanical evaluation of orthotopically implanted bileaflet mechanical aortic valves in adult domestic sheep. Three adult sheep (mean age 22 weeks, mean weight 76 kg) underwent aortic valve replacement using 19-mm bileaflet aortic valves. Standard cardiopulmonary bypass techniques were followed, including mild hemodilution, systemic hypothermia, and cardioplegic arrest. After performing a left fourth intercostal thoracotomy, the valves were placed using interrupted 3-0 Ticron (Davis + Geck) inverted mattress sutures through a transverse aortotomy. The average cardiopulmonary bypass time was 58+/-1 min. No chronic anticoagulation was used. There were no surgical complications. All three animals (100%) remained clinically well until elective sacrifice after postoperative day 150. The average cardiac output for the animals at sacrifice was 3.8+/-1.0 L/min. The mean aortic ejection velocity was 304.7+/-47.3 cm/s and the mean pressure gradient was 24.6+/-6.7 mm Hg. There was no clinically significant thrombus formation or paravalvular leaks. Thus, we have demonstrated that it is technically feasible to orthotopically implant mechanical aortic valves in sheep. There are several features that contribute to the success of this model, including use of a transverse aortotomy, adequate de-airing, and the use of mild hemodilution during bypass. We believe that this model is reproducible and can be used to study other valve designs. In addition, this model allows for site-specific preclinical assessment of new or modified mechanical heart valves.
No takes yet. Share an insight, caveat, or question.
Salerno et al. (1998) studied Aortic valve replacement model (n=3). Orthotopic implantation of 19-mm bileaflet mechanical aortic valves was evaluated on Survival and clinical well-being. Orthotopic implantation of 19-mm bileaflet mechanical aortic valves in adult sheep was technically feasible, with 100% survival to 150 days and no clinically significant thrombus or paravalvular leaks.
Synapse has enriched 10 related papers. Consider them for comparative context: