Key result
In a rabbit ventricular computer model, the presence of intramural blood vessels accelerated reentry termination, resulting in fewer defibrillation failures (5 vs 8) compared to a simplified model.
Population
Highly anatomically detailed rabbit ventricular slice bidomain computer model constructed from 25-μm…
Comparison
Biphasic shocks applied using a realistic… vs Equivalent simplified model with intramural…
Design
Preclinical
Authors
Loading...
Computer models with intramural vessels suggest better defibrillation efficacy; leaves open translation to clinical shock protocols.
Intramural blood vessels >200 μm in diameter facilitate more effective elimination of existing wavefronts and successful defibrillation by acting as virtual electrodes.
Bishop et al. (2011) studied Ventricular fibrillation. Anatomically detailed model with blood vessels vs. Simplified model with intramural cavities filled in was evaluated on Defibrillation failure. In a rabbit ventricular computer model, the presence of intramural blood vessels accelerated reentry termination, resulting in fewer defibrillation failures (5 vs 8) compared to a simplified model.