Key result
Four immunoassay methods (two RIAs, two ELISAs) for measuring serum acid-labile subunit were highly correlated across 125 sera from various patient groups.
Why the study?
Do different immunoassay methods (RIAs and ELISAs) yield correlated measurements of serum acid-labile subunit (ALS)?
Observational (n=125)
Do different immunoassay methods (RIAs and ELISAs) yield correlated measurements of serum acid-labile subunit (ALS)?
A variety of immunoassay formats and reagents can yield highly correlated and clinically useful serum ALS values.
This is the authors' abstract. We don't add key points for this paper.
The acid-labile subunit (ALS) of the high molecular weight insulin-like growth factor binding protein complex is a liver-derived glycoprotein which is regulated by growth hormone and serves as a serum marker of growth hormone action. We have compared the measurement of ALS by four immunoassay methods (two RIAs, two ELISAs) utilizing various polyclonal and monoclonal antibodies raised against natural or recombinant human ALS, or synthetic ALS peptides. Despite the variety of methodologies and reagents, results obtained by the four methods were highly correlated for 125 sera from various patient groups, and when compared for individual groups of sera from healthy children and adults, growth hormone-deficient children and adults, and subjects with acromegaly. Some weaker correlations among methods were seen when measuring ALS levels in groups of sera from pregnant subjects and subjects with chronic renal failure. An assay using antibodies raised against recombinant ALS yielded lower apparent values than the other methods in patient sera, the discrepancy probably being attributable to a difference in standardization. We conclude that a variety of assay formats and reagents can yield serum ALS values of potential clinical utility.
Answers are grounded in this paper and cite their sources.
Correlated ALS values across immunoassays support method comparability in research; leaves open clinical standardization.
No takes yet. Share an insight, caveat, or question.
Baxter et al. (2000) conducted an observational in Various patient groups (healthy, growth hormone-deficient, acromegaly, pregnant, chronic renal failure) (n=125). Four immunoassay methods (two RIAs, two ELISAs) was evaluated on Correlation of ALS measurements among four immunoassay methods. Four immunoassay methods (two RIAs, two ELISAs) for measuring serum acid-labile subunit were highly correlated across 125 sera from various patient groups.
Synapse has enriched 10 related papers. Consider them for comparative context: