Key result
Axillary CIED implantation in pediatric patients was associated with a 6-unit higher total Pediatric QOL Inventory score compared to the infraclavicular approach.
Why the study?
Does axillary CIED implant location improve scar perception and quality of life in pediatric patients compared to the standard infraclavicular approach?
Cohort (n=141)
Yes
Does axillary CIED implant location improve scar perception and quality of life in pediatric patients compared to the standard infraclavicular approach?
Answers are grounded in this paper and cite their sources.
Axillary implantation of CIEDs in pediatric patients significantly improves quality of life and scar perception compared to the standard infraclavicular approach.
BACKGROUND: Axillary implant location is an alternative implant location in patients for cardiac implantable electronic devices (CIEDs) for the purposes of improved cosmetic outcome. The impact from the patient's perspective is unknown. The purpose of this study was to compare scar perception scores and quality of life (QOL) in pediatric patients with axillary CIED implant location versus the standard infraclavicular approach. METHODS: This is a multicenter prospective study conducted at eight pediatric centers and it includes patients aged from 8 to 18 years with a CIED. Patients with prior sternotomy were excluded. Scar perception and QOL outcomes were compared between the infraclavicular and axillary implant locations. RESULTS: A total of 141 patients (83 implantable cardioverter defibrillator [ICD]/58 pacemakers) were included, 55 with an axillary device and 86 with an infraclavicular device. Patients with an ICD in the axillary position had better perception of scar appearance and consciousness. Patients in the axillary group reported, on average, a total Pediatric QOL Inventory score that was 6 (1, 11) units higher than the infraclavicular group, after adjusting for sex and race (P = 0.02). CONCLUSIONS: QOL is significantly improved in axillary in comparison to the infraclavicular CIED position, regardless of device type. Scar perception is improved in patients with ICD in the axillary position.
No takes yet. Share an insight, caveat, or question.
Gist et al. (2018) conducted a cohort in Cardiac implantable electronic devices (CIEDs) (n=141). Axillary CIED implant location vs. Standard infraclavicular approach was evaluated on Total Pediatric QOL Inventory score (MD 6, 95% CI 1-11, p=0.02). Axillary CIED implantation in pediatric patients was associated with a 6-unit higher total Pediatric QOL Inventory score compared to the infraclavicular approach.
Synapse has enriched 10 related papers. Consider them for comparative context: