Why the study?
Data regarding low anterior axillary implantation and its long-term outcomes remain limited for patients with limited bilateral pectoral access after CIED explantation/extraction for infection.
Is low anterior axillary CIED implantation feasible and safe in patients with limited pectoral access requiring reimplantation after device infection?
Is low anterior axillary CIED implantation feasible and safe in patients with limited pectoral access requiring reimplantation after device infection?
Low anterior axillary CIED implantation is a feasible and safe alternative approach for patients who lack conventional pectoral access due to prior device infection.
Answers are grounded in this paper and cite their sources.
May offer alternative site in select patients with limited pectoral access; leaves open need for larger confirmatory trials.
Background Reimplantation of cardiac implantable electronic devices (CIEDs) after system explantation/extraction for infection is particularly challenging in patients with limited bilateral pectoral access. Data regarding low anterior axillary implantation and its long-term outcomes remain limited. Objective To evaluate the feasibility, safety, defibrillation performance, and long-term outcomes of low anterior axillary CIED implantation in patients unsuitable for conventional pectoral reimplantation. Methods Eleven consecutive patients undergoing CIED reimplantation after prior device explantation/extraction for infection were included. All procedures were performed using a low anterior axillary approach with extrathoracic axillary venous access and posterior submuscular generator positioning. Implantable cardioverter-defibrillator (ICD) recipients underwent intraoperative defibrillation threshold (DFT) testing. Procedural characteristics, electrical performance, and long-term clinical outcomes were analyzed retrospectively. Results Mean age was 57 ± 17 years, and 82% of patients were male. Implanted systems included single-chamber pacemakers (18%), dual-chamber pacemakers (27%), and ICDs (55%). Procedural success was achieved in all patients without acute major complications. All ICD recipients demonstrated successful DFT testing with ventricular fibrillation termination using a 25-J shock and adequate safety margins. During a mean follow-up of 37 ± 26 months, one patient (9%) developed recurrent infection requiring system removal. No inappropriate shocks, lead-related complications, or device-related deaths occurred. Serial device interrogation demonstrated stable pacing, sensing, and impedance parameters throughout follow-up. Conclusion Low anterior axillary CIED implantation appears to be a feasible and effective alternative for selected patients with limited pectoral access after device infection, providing acceptable defibrillation performance, stable long-term electrical function, and favorable clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Çay et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: