Answers are grounded in this paper and cite their sources.
Inhibitory properties of the expired antibiotic ceftriaxone against corrosion and hydrogenation of St3 carbon steel, widely used in the oil and gas industry, were studied in simulated formation waters from the NACE (National Association of Corrosion Engineers) and M1 oil and gas fields containing 400 mg/L H2S. Drug concentration varied between 25 and 200 mg/L. Protective effect of ceftriaxone (200 mg/L) was 63 and 85%, according to daily gravimetric tests in NACE and M1 media, respectively. Concomitant administration of 0.5 mM KCNS with ceftriaxone increased the protective effect to 96% in the M1 + 400 mg/L H2S medium. Analysis of the polarization curves showed that ceftriaxone primarily inhibits the cathodic process in both media. Using impedance spectroscopy, it was demonstrated that ceftriaxone adsorption on steel follows the Langmuir isotherm. Ceftriaxone’s inhibition of hydrogen diffusion into the metal and its bactericidal properties against sulfate-reducing bacteria were assessed.
No takes yet. Share an insight, caveat, or question.
Tsygankova et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: