Key result
Tissue Doppler echocardiography E/Ea ratios provided similar accuracy to BNP for predicting decompensated heart failure with preserved ejection fraction.
Why the study?
Does Tissue Doppler echocardiography (E/Ea ratio) provide similar diagnostic accuracy to BNP for predicting decompensated heart failure with preserved LV systolic function in patients with acute dyspnea?
Observational (n=70)
Does Tissue Doppler echocardiography (E/Ea ratio) provide similar diagnostic accuracy to BNP for predicting decompensated heart failure with preserved LV systolic function in patients with acute dyspnea?
Answers are grounded in this paper and cite their sources.
Tissue Doppler echocardiography (E/Ea ratio) is highly accurate for diagnosing decompensated HF with preserved ejection fraction in the emergency setting and provides independent additive value to BNP.
BACKGROUND: Tissue Doppler echocardiography provides a reliable noninvasive estimation of left ventricular (LV) filling pressures irrespective of LV ejection fraction. However, the diagnostic accuracy of E/Ea ratio has not been adequately determined in patients with suspected heart failure (HF) with preserved LV systolic function in the acute care setting. OBJECTIVE: To investigate the accuracy of E/Ea ratio in the emergency diagnosis of decompensated HF with preserved LV systolic function. METHODS: Seventy patients with a LV ejection fraction >or=45%, 32 with decompensated HF (77 +/- 12 years of age), and 38 with noncardiac cause of acute dyspnea (74 +/- 12) were enrolled. B-type natriuretic peptide (BNP) was measured on admission; lateral, septal and average E/Ea ratios were calculated within 24 hours. RESULTS: Using receiver-operating characteristic curves to evaluate diagnostic performance, BNP (AUC of 0.875, P < 0.0001) and E/Ea ratios (AUC of 0.90-0.92, P < 0.0001) provided similar accuracy for predicting decompensated HF. Optimal cutoffs were 146 pg/ml for BNP (sensitivity and specificity of 90.6% and 76.3%), 9.8 for lateral E/Ea (83.3% and 88.9%), 12.7 for septal E/Ea (76.7% and 91.4%), and 11.5 for average E/Ea ratio (80% and 94.3%). On multivariate logistic regression analysis, average E/Ea ratio yielded independent additional information to a model based on the clinical judgment and BNP level according to the standard cutoff of 100 pg/ml. CONCLUSIONS: Tissue Doppler echocardiography is accurate for predicting decompensated HF with preserved LV systolic function and may be used as a diagnostic complement to inconclusive BNP level in this setting.
No takes yet. Share an insight, caveat, or question.
Arquès et al. (2005) conducted an observational in Decompensated heart failure with preserved LV systolic function (n=70). Tissue Doppler echocardiography (E/Ea ratio) vs. B-type natriuretic peptide (BNP) was evaluated on Emergency diagnosis of decompensated HF (AUC 0.90-0.92, p=<0.0001). Tissue Doppler echocardiography E/Ea ratios provided similar accuracy to BNP for predicting decompensated heart failure with preserved ejection fraction.
Synapse has enriched 10 related papers. Consider them for comparative context: