Key result
Aortic valve replacement using the stentless porcine aortic valve resulted in a 6% hospital mortality rate and competent valves in 96% of patients at 41 months follow-up.
Why the study?
Does aortic valve replacement using a stentless porcine aortic valve provide safe and effective clinical and hemodynamic outcomes in patients requiring aortic valve replacement?
Observational (n=100)
Does aortic valve replacement using a stentless porcine aortic valve provide safe and effective clinical and hemodynamic outcomes in patients requiring aortic valve replacement?
The use of a stentless porcine aortic valve for aortic valve replacement demonstrated excellent clinical results, stable valve coaptation, and improved left ventricular function at 41 months follow-up.
Answers are grounded in this paper and cite their sources.
Supports feasibility of stentless porcine AVR in selected cases; leaves open need for randomized trials versus stented valves.
From May 1990 to August 1993, 100 patients underwent aortic valve replacement using the stentless porcine aortic valve. There were 69 males and 31 females. The mean age was 36 (range 11-76) years. Of 70 patients under 40 years of age, 20 were less than 20 years old. Indications included rheumatic heart sequelae in 55 patients (first valve replacement), prosthetic failure in 20, endocarditis in 13, congenital aortic bicuspid valve in four, degenerative disease in four and senile calcified aortic valves in four. Twenty patients had aortic annular related pathology. There were 15 associated surgical procedures. Forty-three patients required aortic root enlargement. There were approximately equal numbers of patients in New York Heart Association (NYHA) functional classes III and IV. The hospital mortality rate was 6%; 14 patients who experienced hospital morbidity had a full recovery. Two late reoperations were performed in patients with primary valve endocarditis; their recovery was uneventful. Four late deaths were not valve related. Comparative echo Doppler analysis before and after operation demonstrated good improvement of left ventricular function in nearly all patients. The valve was competent in 96% of patients and the remainder displayed minor jets without haemodynamic significance. The valve coaptation was stable in all patients. Use of the stentless porcine aortic valve in this first 100 patients has provided excellent clinical results with a follow-up of 41 months. Further follow-up and close observation will be required to analyse the outcome of this new valve and procedure with time.
No takes yet. Share an insight, caveat, or question.
Vrandecic et al. (1994) conducted an observational in Aortic valve disease requiring replacement (n=100). Stentless porcine aortic valve was evaluated on Hospital mortality. Aortic valve replacement using the stentless porcine aortic valve resulted in a 6% hospital mortality rate and competent valves in 96% of patients at 41 months follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: