Key result
Editing ectopic beats with interpolation or deletion corrected the bias in fractal measurements of non-linear heart rate dynamics caused by unedited ectopic beats.
Why the study?
Does editing of ectopic beats using interpolation or deletion correct bias in measurements of short-term non-linear heart rate dynamics compared to unedited recordings?
Observational (n=753)
Does editing of ectopic beats using interpolation or deletion correct bias in measurements of short-term non-linear heart rate dynamics compared to unedited recordings?
Proper editing of ectopic beats using interpolation or deletion is necessary to correct bias in fractal measurements of short-term non-linear heart rate dynamics.
Supports routine ectopic beat editing for accurate fractal HRV; leaves open effects on clinical risk stratification.
Non-linear heart rate (HR) dynamics characterizes the fractal properties and complexity of the variations in HR. Ventricular and supraventricular ectopic beats might introduce a mathematical artefact to the analyses on sinus rhythm. We therefore evaluated the effects of different editing practices for ectopic beats such that 753 40-min ECG recordings were (i) not edited for the ectopic beats, or the ectopic beats were edited with (ii) an interpolation or with (iii) a deletion method before the analyses of non-linear HR dynamics. The non-linear HR dynamics analyses included detrended fluctuation analysis (DFA), approximate entropy, symbolic dynamics (SymDyn), fractal dimension and return map (RM). We found that the short-term scaling exponent (alpha1) of DFA, forbidden words of SymDyn and RM were sensitive measurements to the ectopic beats and there were strong correlations between these measurements and the number of ectopic beats. In addition, the unedited ectopic beats significantly lowered the stability of these measurements. However, the editing either with interpolation or deletion method corrected the measurements for the bias caused by the ectopic beats. On the contrary, the entropy measurements were not as sensitive to the ectopic beats. In conclusion, the ectopic beats affect the non-linear HR dynamics of sinus rhythm differently, causing a more marked bias in fractal than in complexity measurements of non-linear HR dynamics. This erroneous effect of ectopic beats can be corrected with a proper editing of these measurements. Therefore, there is an obvious need for standardized editing practices for ectopic beats before the analysis of non-linear HR dynamics.
No takes yet. Share an insight, caveat, or question.
Tarkiainen et al. (2007) conducted an observational in Ectopic beats (n=753). Editing of ectopic beats (interpolation or deletion) vs. Unedited ectopic beats was evaluated on Non-linear heart rate dynamics (DFA, approximate entropy, SymDyn, fractal dimension, return map). Editing ectopic beats with interpolation or deletion corrected the bias in fractal measurements of non-linear heart rate dynamics caused by unedited ectopic beats.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: