Key result
Real-time transthoracic echocardiography guidance during fluoroscopic right ventricular lead placement resulted in lead repositioning to a confirmed septal position in 38.5% of patients.
Why the study?
The accuracy of fluoroscopy in predicting septal placement of RV leads is poor.
Does real-time transthoracic echocardiography guidance improve true septal placement of right ventricular leads in patients undergoing transvenous pacemaker or ICD placement?
Observational (n=26)
No
Does real-time transthoracic echocardiography guidance improve true septal placement of right ventricular leads in patients undergoing transvenous pacemaker or ICD placement?
Real-time transthoracic echocardiography is a feasible adjunct to fluoroscopy during right ventricular lead placement, leading to lead repositioning in over a third of patients to ensure true septal positioning.
Answers are grounded in this paper and cite their sources.
May aid true septal RV lead placement; hypothesis-generating and requires randomized trials before practice change.
INTRODUCTION: Accuracy of fluoroscopy in predicting septal placement of the right ventricular (RV) leads is poor. This pilot study evaluated the feasibility and impact of real-time transthoracic echocardiogram (TTE) during RV lead placement. METHOD: Consecutive patients undergoing transvenous RV lead placement and had a point of care ultrasound team available for TTE guidance were included in the study. TTE was performed to confirm or refute the septal position of RV lead initially positioned using fluoroscopy; leads were repositioned until a septal position was confirmed on TTE. The primary outcome measured was whether the use of TTE resulted in lead repositioning. RESULT: Among the 26 patients included in the study, real-time TTE during RV lead placement resulted in reposition of the lead to a septal position in 38.5% of patients. CONCLUSION: Use of real-time TTE guidance during fluoroscopic RV lead placement is feasible and can aid in confirming a septal position.
No takes yet. Share an insight, caveat, or question.
Yan et al. (2021) conducted an observational in Patients undergoing transvenous right ventricular lead placement (n=26). Real-time transthoracic echocardiography (TTE) guidance was evaluated on Whether the use of TTE resulted in lead repositioning. Real-time transthoracic echocardiography guidance during fluoroscopic right ventricular lead placement resulted in lead repositioning to a confirmed septal position in 38.5% of patients.