Key result
Pacing-induced ischemia shifted the diastolic pressure-volume curves upward in filling beats, whereas nonfilling beats fell on the fully relaxed pressure-volume relation of the normally perfused heart.
Why the study?
Does left ventricular filling contribute to the upward shift of the diastolic pressure-volume curve during pacing-induced ischemia in dogs?
Does left ventricular filling contribute to the upward shift of the diastolic pressure-volume curve during pacing-induced ischemia in dogs?
Left ventricular filling is necessary for the upward shift of the diastolic pressure-volume curve during pacing-induced ischemia, suggesting stretch activation or length-dependent changes in calcium sensitivity contribute to this phenomenon.
Answers are grounded in this paper and cite their sources.
LV filling drives ischemic diastolic shifts in dogs; leaves open human translation and stretch-activation therapies.
The reversible upward shift of the diastolic pressure-volume curve that occurs during pacing-induced ischemia has not been fully explained by increases in passive chamber stiffness or reductions in relaxation rate. We measured the fully relaxed pressure-volume relation defined by both filling and nonfilling beats and the isovolumic relaxation time constant in nonfilling beats before and during demand ischemia using our in situ left ventricular volume clamping technique in 10 dogs. Pacing-induced ischemia shifted the diastolic pressure-volume curves in filling beats upward compared with the end-diastolic pressure-volume relation of the normally perfused heart. In contrast, the end-diastolic points for nonfilling beats during pacing-induced ischemia fell on the fully relaxed pressure-volume relation defined by the normally perfused heart. Left ventricular filling per se was necessary for the upward shift of the diastolic pressure-volume curve observed during pacing-induced ischemia. We speculate that active force developed during diastole induced by stretch activation or, perhaps, length-dependent changes in calcium sensitivity of the myofilaments in the ischemic myocardium due to stretch of the myocardium during rapid diastolic filling may contribute to the upward shift of the diastolic pressure-volume curve observed during pacing-induced ischemia.
No takes yet. Share an insight, caveat, or question.
Shintani et al. (1994) studied Pacing-induced ischemia (n=10). Pacing-induced ischemia with filling beats vs. Normally perfused heart / nonfilling beats was evaluated on Diastolic pressure-volume curve shift. Pacing-induced ischemia shifted the diastolic pressure-volume curves upward in filling beats, whereas nonfilling beats fell on the fully relaxed pressure-volume relation of the normally perfused heart.
Synapse has enriched 10 related papers. Consider them for comparative context: